Comparison of the Frequency of Thrombocytopenia After Transfemoral Transcatheter Aortic Valve Implantation Between Balloon-Expandable and Self-Expanding Valves
- Source :
- The American Journal of Cardiology. 123:1120-1126
- Publication Year :
- 2019
- Publisher :
- Elsevier BV, 2019.
-
Abstract
- Thrombocytopenia after transcatheter aortic valve implantation (TAVI) is common and has been related to worse clinical outcomes. Comparison of platelet kinetics among different types of valves is limited. Our objectives were to analyze the differences in drop platelet count (DPC) between balloon-expandable valves (BEVs) and self-expanding valves and their prognostic implications after TAVI. Patients who underwent transfemoral TAVI from 2008 to 2016 were included. Exclusion criteria were severe baseline thrombocytopenia and periprocedural death. Postprocedural platelet counts were collected. Two groups were created: DPC ≤30 and DPC30%. Valve Academic Research Consortium-2 criteria were used to define outcomes. Study population included 609 patients (age 84.7 ± 6.0, 46.6% males). The mean DPC was 32.5 ± 13.9%. The DPC was higher in the BEV arm (33.9 ± 14.2 vs 30.7 ± 13.4%, p = 0.006), and the nadir was reached later in comparison to the self-expanding valve arm (3.0 ± 1.3 vs 2.5 ± 1.1 days, p0.001). After multivariable analysis, the use of BEV, known coronary artery disease, and left ventricle ejection fraction were the factors associated with a higher rate of DPC30%. At 30 days, the DPC30% was related with a higher rate of life-threatening and/or major bleeding (6.8 vs 2.1%, p = 0.009) and death (3.5 vs 0.8%, p = 0.036). At 1 year, the difference in mortality disappeared. In conclusion, in this cohort of patients, the use of BEV seems to be associated with a higher risk of DPC after TAVI. A DPC ≥30% was related with increased risk of life-threatening and/or major bleeding and death at 30 days. Larger and prospective studies are needed to understand this phenomenon.
- Subjects :
- Male
medicine.medical_specialty
Transcatheter aortic
030204 cardiovascular system & hematology
Prosthesis Design
Transcatheter Aortic Valve Replacement
03 medical and health sciences
Postoperative Complications
0302 clinical medicine
Internal medicine
medicine
Humans
Prospective Studies
030212 general & internal medicine
Prospective cohort study
Aged, 80 and over
Platelet Count
business.industry
Incidence
Follow up studies
Aortic Valve Stenosis
Thrombocytopenia
Survival Rate
Balloon expandable stent
Increased risk
Heart Valve Prosthesis
Cohort
Cardiology
Population study
Female
France
Cardiology and Cardiovascular Medicine
business
Major bleeding
Follow-Up Studies
Subjects
Details
- ISSN :
- 00029149
- Volume :
- 123
- Database :
- OpenAIRE
- Journal :
- The American Journal of Cardiology
- Accession number :
- edsair.doi.dedup.....a49cab02280d279b7f7a4e9bbc8a37e7
- Full Text :
- https://doi.org/10.1016/j.amjcard.2018.12.036