Back to Search
Start Over
GASTONE64: A new front-end ASIC for the cylindrical GEM Inner Tracker of KLOE-2 experiment at DAΦNE
- Source :
- Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 732:523-525
- Publication Year :
- 2013
- Publisher :
- Elsevier BV, 2013.
-
Abstract
- GASTONE64 (Gem Amplifier Shaper Tracking ON Events) is a novel 64-channel mixed analog-digital ASIC developed to readout the cylindrical GEM inner tracking detector of the KLOE-2 apparatus at the e+e− DA Φ NE collider. It has been designed in the CMOS 0.35 μ m technology and each analog channel is made of preamplifier, shaper and discriminator. The expected input charge ranges between few fC up to 40 fC, the charge sensitivity is 16 mV/fC while the equivalent input noise charge (ENC) is 800 e−+40 e−/pF. The discriminated signals are read-out using a 100 MBit/s LVDS serial data link. The power consumption is about 6 mW/channel.
Details
- ISSN :
- 01689002
- Volume :
- 732
- Database :
- OpenAIRE
- Journal :
- Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Accession number :
- edsair.doi.dedup.....a47bb5e710795903de6898f1c9a75cbe