Abstract

GASTONE64 (Gem Amplifier Shaper Tracking ON Events) is a novel 64-channel mixed analog-digital ASIC developed to readout the cylindrical GEM inner tracking detector of the KLOE-2 apparatus at the e+e− DA Φ NE collider. It has been designed in the CMOS 0.35 μ m technology and each analog channel is made of preamplifier, shaper and discriminator. The expected input charge ranges between few fC up to 40 fC, the charge sensitivity is 16 mV/fC while the equivalent input noise charge (ENC) is 800 e−+40 e−/pF. The discriminated signals are read-out using a 100 MBit/s LVDS serial data link. The power consumption is about 6 mW/channel.