Back to Search Start Over

Setup for meV-resolution inelastic X-ray scattering measurements and X-ray diffraction at the Matter in Extreme Conditions endstation at the Linac Coherent Light Source

Authors :
M. Oliver
Stefan Funk
Benjamin K. Ofori-Okai
Eric Galtier
Giulio Monaco
Gianluca Gregori
Maxence Gauthier
Florian Condamine
J. B. Hastings
Luke Fletcher
Siegfried Glenzer
Karen Appel
Bob Nagler
Hae Ja Lee
Thomas G. White
A. Rigby
Ulf Zastrau
C. Schoenwaelder
B. B. L. Witte
Th. Tschentscher
Sebastian Goede
J. B. Kim
Emma McBride
F. Dallari
Chandra Curry
Adrien Descamps
Peihao Sun
Laboratoire pour l'utilisation des lasers intenses (LULI)
Commissariat à l'énergie atomique et aux énergies alternatives (CEA)-École polytechnique (X)-Sorbonne Université (SU)-Université Paris-Saclay-Centre National de la Recherche Scientifique (CNRS)
Commissariat à l'énergie atomique et aux énergies alternatives (CEA)-École polytechnique (X)-Sorbonne Université (SU)-Centre National de la Recherche Scientifique (CNRS)
Source :
Rev.Sci.Instrum., 22nd Topical Conference on High-Temperature Plasma Diagnostics, 22nd Topical Conference on High-Temperature Plasma Diagnostics, Apr 2018, San Diego, United States. pp.10F104, ⟨10.1063/1.5039329⟩
Publication Year :
2018
Publisher :
HAL CCSD, 2018.

Abstract

International audience; We describe a setup for performing inelastic X-ray scattering and X-ray diffraction measurements at the Matter in Extreme Conditions (MEC) endstation of the Linac Coherent Light Source. This technique is capable of performing high-, meV-resolution measurements of dynamic ion features in both crystalline and non-crystalline materials. A four-bounce silicon (533) monochromator was used in conjunction with three silicon (533) diced crystal analyzers to provide an energy resolution of ∼50 meV over a range of ∼500 meV in single shot measurements. In addition to the instrument resolution function, we demonstrate the measurement of longitudinal acoustic phonon modes in polycrystalline diamond. Furthermore, this setup may be combined with the high intensity laser drivers available at MEC to create warm dense matter and subsequently measure ion acoustic modes.

Details

Language :
English
Database :
OpenAIRE
Journal :
Rev.Sci.Instrum., 22nd Topical Conference on High-Temperature Plasma Diagnostics, 22nd Topical Conference on High-Temperature Plasma Diagnostics, Apr 2018, San Diego, United States. pp.10F104, ⟨10.1063/1.5039329⟩
Accession number :
edsair.doi.dedup.....a3596da4eb23913c30e0bb021cafd367