Back to Search Start Over

Nanozyme chemiluminescence paper test for rapid and sensitive detection of SARS-CoV-2 antigen

Authors :
Chenhui Ju
Jinghua Yan
Demin Duan
Chao Han
Dan Liu
Xuehui Chen
Rui Shi
Xiyun Yan
Source :
Biosensors and Bioelectronics, Biosensors & Bioelectronics
Publication Year :
2021
Publisher :
Elsevier BV, 2021.

Abstract

COVID-19 has evolved into a global pandemic. Early and rapid detection is crucial to control of the SARS-CoV-2 transmission. While representing the gold standard for early diagnosis, nucleic acid tests for SARS-CoV-2 are often complicated and time-consuming. Serological rapid antibody tests are characterized by high rates of false-negative diagnoses, especially during early infection. Here, we developed a novel nanozyme-based chemiluminescence paper assay for rapid and sensitive detection of SARS-CoV-2 spike antigen, which integrates nanozyme and enzymatic chemiluminescence immunoassay with the lateral flow strip. The core of our paper test is a robust Co–Fe@hemin-peroxidase nanozyme that catalyzes chemiluminescence comparable with natural peroxidase HRP and thus amplifies immune reaction signal. The detection limit for recombinant spike antigen of SARS-CoV-2 was 0.1 ng/mL, with a linear range of 0.2-100 ng/mL. Moreover, the sensitivity of test for pseudovirus could reach 360 TCID50/mL, which was comparable with ELISA method. The strip recognized SARS-CoV-2 antigen specifically, and there was no cross reaction with other coronaviruses or influenza A subtypes. This testing can be completed within 16 min, much shorter compared to the usual 1-2 h required for currently used nucleic acid tests. Furthermore, signal detection is feasible using the camera of a standard smartphone. Ingredients for nanozyme synthesis are simple and readily available, considerably lowering the overall cost. In conclusion, our paper test provides a high-sensitive point-of-care testing (POCT) approach for SARS-CoV-2 antigen detection, which should greatly facilitate early screening of SARS-CoV-2 infections, and considerably lower the financial burden on national healthcare resources.<br />Highlights • Point-of-care antigen tests for screening of SARS-CoV-2 infection were established. • Chemiluminescence improves sensitivity of paper test and benefits early screening. • Nanozyme with high peroxidase activity and stability catalyzes chemiluminescence. • Nanozyme chemiluminescence paper test brings high efficiency and low cost.

Details

ISSN :
09565663
Volume :
173
Database :
OpenAIRE
Journal :
Biosensors and Bioelectronics
Accession number :
edsair.doi.dedup.....a1c220e814f440bfbc43b6cc64641392