Back to Search Start Over

3D Modeling of Blood Flow in Simulated Abdominal Aortic Aneurysm

Authors :
Mauricio Gonzalez-Urquijo
Erika Garza Ibarra
Raul Garza de Zamacona
Ana Karen Martinez Mendoza
Miranda Zamora Iribarren
Mario Alejandro Fabiani
Marcos David Moya Bencomo
Source :
Vascular and Endovascular Surgery. 55:677-683
Publication Year :
2021
Publisher :
SAGE Publications, 2021.

Abstract

Background: Besides biological factors, abdominal aortic aneurysm rupture is also caused by mechanical parameters, which are constantly affecting the wall’s tissue due to their abnormal values. The ability to evaluate these parameters could vastly improve the clinical treatment of patients with abdominal aortic aneurysms. The objective of this study was to develop and demonstrate a methodology to analyze the fluid dynamics that cause the wall stress distribution in abdominal aortic aneurysms, using accurate 3D geometry and a realistic, nonlinear, elastic biomechanical model using a computer-aided software. Methods: The geometry of the abdominal aortic aneurysm; was constructed on a 3D scale using computer-aided software SolidWorks (Dassault Systems SolidWorksCorp., Waltham MA). Due to the complex nature of the abdominal aortic aneurysm geometry, the physiological forces and constraints acting on the abdominal aortic aneurysm wall were measured by using a simulation setup using boundary conditions and initial conditions for different studies such as finite element analysis or computational fluid dynamics. Results: The flow pattern showed an increase velocity at the angular neck, followed by a stagnated flow inside the aneurysm sack. Furthermore, the wall shear stress analysis showed to focalized points of higher stress, the top and bottom of the aneurysm sack, where the flow collides against the wall. An increase of the viscosity showed no significant velocity changed but results in a slight increase in overall pressure and wall shear stress. Conclusions: Conducting computational fluid dynamics modeling of the abdominal aortic aneurysm using computer-aided software SolidWorks (Dassault Systems SolidWorksCorp., Waltham MA) proves to be an insightful approach for the clinical setting. The careful consideration of the biomechanics of the abdominal aortic aneurysm may lead to an improved, case-specific prediction of the abdominal aortic aneurysm rupture potential, which could significantly improve the clinical management of these patients.

Details

ISSN :
19389116 and 15385744
Volume :
55
Database :
OpenAIRE
Journal :
Vascular and Endovascular Surgery
Accession number :
edsair.doi.dedup.....a02fe37963cb6de4411d87365c6e8c84
Full Text :
https://doi.org/10.1177/15385744211012926