Back to Search
Start Over
Tissue reactions evoked by porous and plane surfaces made out of silicon and titanium
- Source :
- IEEE Transactions on Biomedical Engineering; 49(4), pp 392-399 (2002)
- Publication Year :
- 2002
-
Abstract
- Square-shaped silicon or titanium implants with plane or porous surfaces surrounded by a rim of silicone were implanted in the rat abdominal wall for evaluation of the tissue response after one, six, or 12 weeks. Cell damage was identified as increased membrane permeability using fluorescence microscopy by injection of propidium iodide prior to the killing of the rats. Capsule thickness and immunohistochemical quantification of macrophages were used as a further measure of the foreign-body reaction. There were no significant differences in capsular cell densities for macrophages, total cells (macrophages, fibroblasts, and other cells), or necrotic cells at the different time points for the four surfaces studied. However, significant differences in the kinetics of the response were found between plane surfaces compared with porous ones. Both types of plane surfaces developed a significant increase in capsule thickness over time in contrast to the porous implants. Porous silicon displayed a significant decrease in total cells in the reactive capsule over time. Furthermore, porous silicon and titanium surfaces displayed a significant decrease in total cell numbers at the implant interface between six and 12 weeks. The present study demonstrated that implanted silicon elicited soft-tissue reactions comparable to that of titanium.
- Subjects :
- Male
Silicon
Materials science
Cell Membrane Permeability
Membrane permeability
Image Processing
Medical Engineering
adverse effects [Prostheses and Implants]
Biomedical Engineering
chemistry.chemical_element
Biocompatible Materials
Porous silicon
Prosthesis Design
pathology [Foreign-Body Reaction]
Fluorescence
Statistics, Nonparametric
Immunoenzyme Techniques
Rats, Sprague-Dawley
chemistry.chemical_compound
Silicone
Computer-Assisted
Image Processing, Computer-Assisted
Animals
Nonparametric
Propidium iodide
Non-U.S. Gov't
Abdominal Muscles
Titanium
Microscopy
Animal
Foreign-Body Reaction
Statistics
technology, industry, and agriculture
Capsule
Prostheses and Implants
equipment and supplies
Rats
chemistry
Microscopy, Fluorescence
Implant
Sprague-Dawley
Support
Biomedical engineering
Subjects
Details
- ISSN :
- 00189294 and 15582531
- Volume :
- 49
- Issue :
- 4
- Database :
- OpenAIRE
- Journal :
- IEEE transactions on bio-medical engineering
- Accession number :
- edsair.doi.dedup.....9de27ad037c278a992fa259c296122f7