Back to Search
Start Over
Maternal Serum Inhibin-A Augments the Value of Maternal Serum PlGF and of sFlt-1/PlGF Ratio in the Prediction of Preeclampsia and/or FGR Near Delivery—A Secondary Analysis
- Source :
- Reproductive Medicine, Volume 2, Issue 1, Pages 5-49
- Publication Year :
- 2021
- Publisher :
- MDPI AG, 2021.
-
Abstract
- Objective: We previously provided evidence to confirm that maternal serum levels of soluble Fms-like tyrosine kinase-1 (sFlt-1), placental growth factor (PlGF), and their ratio are useful tools to direct the management of preeclampsia (PE), fetal growth restriction (FGR), and PE+FGR near delivery. In this secondary analysis, we further examine the potential additive value of maternal serum Inhibin-A, which is a hormone marker of the transforming growth factor family, to the accuracy provided by maternal serum PlGF and sFlt-1. Methods: We conducted a secondary analysis where we extracted the data of a cohort of 125 pregnant women enrolled near delivery at the clinics of the University Medical Center of Ljubljana, Slovenia. The dataset included 31 cases of PE, 16 of FGR, 42 of PE+FGR, 15 preterm delivery (PTD), and 21 unaffected controls with delivery of a healthy baby at term. Cases delivered before 34 weeks’ gestation included 10 of PE, 12 of FGR, 28 of PE+FGR, and 6 of PTD. In addition to the recorded demographic characteristics and medical history and the maternal serum levels of PlGF and sFlt-1/PlGF ratio, which were previously published, we evaluated the added value of maternal serum Inhibin-A. The predictive accuracy of each biomarker, their ratios, and combinations were estimated from areas under the curve (AUC) of receiver operating characteristics (ROC) curves, Box and Whisker plots, and by multiple regression. We estimated accuracy by the continuous marker model and a cutoff model. Results: In this study, we combined Inhibin-A with PlGF or with the sFlt-1/PlGF ratio and showed a 10–20% increase in AUCs and 15–45% increase in the detection rate, at 10% false positive rate, of PE, and a lower, but significant, increase for PE+FGR and FGR in all cases but not for FGR in early cases delivered &lt<br />34 weeks. The use of a cutoff model was adequate, although a bit higher accuracy was obtained from the continuous model. The highest correlation was found for PlGF with all three complications. Conclusion: In this secondary analysis, we have found that maternal serum Inhibin-A improves the accuracy of predicting PE and PE+FGR provided by maternal serum angiogenic markers alone, bringing the results to a diagnostic level<br />thus, it could be considered for directing clinical management. Inhibin-A had smaller or no added value for the accuracy of predicting FGR alone, mainly of early cases delivered &lt<br />34 weeks.
- Subjects :
- Placental growth factor
medicine.medical_specialty
placental growth factor
sFlt-1
Ocean Engineering
030204 cardiovascular system & hematology
Inhibin-A
Preeclampsia
preeclampsia
fetal growth restriction
03 medical and health sciences
0302 clinical medicine
Medicine
Cutoff
Water Science and Technology
030219 obstetrics & reproductive medicine
Receiver operating characteristic
business.industry
Obstetrics
Geology
medicine.disease
Cohort
Gestation
Biomarker (medicine)
False positive rate
business
Subjects
Details
- ISSN :
- 26733897
- Volume :
- 2
- Database :
- OpenAIRE
- Journal :
- Reproductive Medicine
- Accession number :
- edsair.doi.dedup.....9d0243e374416cf328c05b232256b3d3