Biomechanical validation of finite element models for two silicone metacarpophalangeal joint implants
- Source :
- Journal of biomechanical engineering. 133(2)
- Publication Year :
- 2011
-
Abstract
- Silicone implants are used for prosthetic arthroplasty of metacarpophalangeal (MCP) joints severely damaged by rheumatoid arthritis. Different silicone elastomer MCP implant designs have 1 Corresponding author. 55 Queen Street East, Suite 800, Toronto, ON, M5C 1R6, Canada. Contributed by the Bioengineering Division of ASME for publication in the JOURNAL OF BIOMECHANICAL ENGINEERING. Manuscript received February 3, 2010; final manuscript received December 19, 2010; accepted manuscript posted December 22, 2010; published online January 31, 2011. Assoc. Editor: Yener N. Yeni. been developed, including the Swanson and the NeuFlex implants. The goal of this study was to compare the in vitro mechanical behavior of Swanson and NeuFlex MCP joint implants. Three-dimensional (3D) finite element (FE) models of the silicone implants were modeled using the commercial software ANSYS and subjected to angular displacement from 0 deg to 90 deg. FE models were validated using mechanical tests of implants incrementally bent from 0 deg to 90 deg in a joint simulator. Swanson size 2 and 4 implants were compared with NeuFlex size 10 and 30 implants, respectively. Good agreement was observed throughout the range of motion for the flexion bending moment derived from 3D FE models and mechanical tests. From 30 deg to 90 deg, the Swanson 2 demonstrated a greater resistance to deformation than the NeuFlex 10 and required a greater bending moment for joint flexion. For larger implant sizes, the NeuFlex 30 had a steeper moment-displacement curve, but required a lower moment than the Swanson 4, due to implant reflexion. On average, the stress generated at the implant hinge from 30 deg to 90 deg was lower in the NeuFlex than in the Swanson. On average, starting from the neutral position of 30 deg for the reflexed NeuFlex implant, higher moments were required to extend the NeuFlex implants to 0 deg compared with the Swanson implants, which returned spontaneously to resting position. Implant toggling within the medullary canals was less in the NeuFlex than in the Swanson. The differential performance of these implants may be useful in implant selection based on the preoperative condition(s) of the joint and specific patient functional needs.
- Subjects :
- Materials science
medicine.medical_treatment
Finite Element Analysis
Biomedical Engineering
Biomechanics
Silicones
Metacarpophalangeal joint
Prostheses and Implants
Biomechanical engineering
Prosthesis
Arthroplasty
Biomechanical Phenomena
Metacarpophalangeal Joint
medicine.anatomical_structure
Physiology (medical)
Materials Testing
medicine
Displacement (orthopedic surgery)
Implant
Stress, Mechanical
Range of Motion, Articular
Range of motion
Biomedical engineering