Back to Search Start Over

Assessment of endothelial function by acetylcholine iontophoresis: impact of inter-electrode distance and electrical cutaneous resistance

Authors :
Pierre Abraham
Georges Leftheriotis
Sébastien Faure
Cyril Puissant
Guillaume Mahé
Sylvain Durand
Anne Humeau-Heurtier
Centre Hospitalier Universitaire d'Angers (CHU Angers)
PRES Université Nantes Angers Le Mans (UNAM)
Biologie Neurovasculaire et Mitochondriale Intégrée (BNMI)
Université d'Angers (UA)-Institut National de la Santé et de la Recherche Médicale (INSERM)-Centre National de la Recherche Scientifique (CNRS)
Motricité, interactions, performance EA 4334 / Movement - Interactions - Performance (MIP)
Université de Nantes - UFR des Sciences et Techniques des Activités Physiques et Sportives (UFR STAPS)
Université de Nantes (UN)-Université de Nantes (UN)-Centre hospitalier universitaire de Nantes (CHU Nantes)-Le Mans Université (UM)
Laboratoire Angevin de Recherche en Ingénierie des Systèmes (LARIS)
Université d'Angers (UA)
Stress Oxydant et Pathologies Métaboliques (SOPAM)
Université d'Angers (UA)-Institut National de la Santé et de la Recherche Médicale (INSERM)
Centre d'Investigation Clinique [Rennes] (CIC)
Université de Rennes 1 (UR1)
Université de Rennes (UNIV-RENNES)-Université de Rennes (UNIV-RENNES)-Hôpital Pontchaillou-Institut National de la Santé et de la Recherche Médicale (INSERM)
CHU Pontchaillou [Rennes]
Motricité, interaction, performance EA 4334 (MIP)
Le Mans Université (UM)-Université de Nantes - UFR des Sciences et Techniques des Activités Physiques et Sportives (UFR STAPS)
Université de Nantes (UN)-Université de Nantes (UN)
Le Mans Université (UM)-Centre hospitalier universitaire de Nantes (CHU Nantes)-Université de Nantes - UFR des Sciences et Techniques des Activités Physiques et Sportives (UFR STAPS)
Université de Rennes (UR)-Hôpital Pontchaillou-Institut National de la Santé et de la Recherche Médicale (INSERM)
Source :
Microvascular Research, Microvascular Research, Elsevier, 2014, 93, pp.114-118. ⟨10.1016/j.mvr.2014.04.001⟩, Microvascular Research, 2014, 93, pp.114-118. ⟨10.1016/j.mvr.2014.04.001⟩
Publication Year :
2014
Publisher :
HAL CCSD, 2014.

Abstract

International audience; OBJECTIVES: Endothelial function can be assessed by acetylcholine (ACh) iontophoresis with single current application. The effect of inter-electrode distance as well as electrical cutaneous resistance (ECR) on ACh dependent vasodilation has never been studied using single current application. The aims of this study are (i) to compare ACh-peak and ECR measured at different inter-electrode distances, (ii) to assess the relationship between ACh-peak and ECR, (iii) and to study the reproducibility of the ECR values. METHODS: Fourteen healthy subjects were included. Using laser speckle contrast imaging, ACh-iontophoreses (0.1 mA, 30s) were performed on the forearm at a 7-day interval with an inter-electrode distance set at 5 cm. Two other inter-electrode distances were also evaluated: 10 cm and 15 cm. ECR was measured during each ACh-iontophoresis as well as the ACh-peak. RESULTS: No statistical difference was found between the ACh-peak values obtained at 5 cm, 10 cm and 15 cm. ECRs were also not statistically different. An inverse relationship (r=-0.60) was found between the ACh-peak and ECR (p\textless0.05). The coefficient of variation of the inter-day reproducibility of the ECR values was 9.1% [6.5%-15.1%] with an intra-class-correlation coefficient of 0.93 [0.81-0.98]. CONCLUSION: Inter-electrode distance ranging from 5 cm to 15 cm changes neither the ACh-peak value nor the ECR value. ECR impacts ACh-peak values.

Details

Language :
English
ISSN :
00262862 and 10959319
Database :
OpenAIRE
Journal :
Microvascular Research, Microvascular Research, Elsevier, 2014, 93, pp.114-118. ⟨10.1016/j.mvr.2014.04.001⟩, Microvascular Research, 2014, 93, pp.114-118. ⟨10.1016/j.mvr.2014.04.001⟩
Accession number :
edsair.doi.dedup.....9bbe277eb8d30b468942e01685e38831