Intraoperative transesophageal echocardiography using high-resolution biplane 7.5 MHz probes with continuous-wave Doppler capability in infants and children with tetralogy of Fallot

Authors :
Shuping Ge
Mary J. Rice
David J. Sahn
Takahiro Shiota
Adnan Cobanoglu
Zheng Gong
Jinping Xu
Source :
The American Journal of Cardiology. 77:539-542
Publication Year :
1996
Publisher :
Elsevier BV, 1996.

Abstract

Our study indicates that (1) the biplane TEE probe provides an accurate assessment of the surgical repair of ToF in infants and children; (2) the longitudinal plane especially offers important information showing right ventricular outflow tract anatomy that cannot be fully defined using conventional transverse plane TEE; and (3) implementation of steerable CW Doppier aids quantification of residual right ventricular outflow tract obstruction, especially when implemented from transgastric views.