Back to Search Start Over

Water vapor retrievals from spectral direct irradiance measured with an EKO MS-711 spectroradiometer—intercomparison with Other Techniques

Authors :
Emilio Cuevas
África Barreto
Ramón Ramos
Omaira García
Jochen Gross
Kees Hoogendijk
Victoria E. Cachorro
Rosa Delia García
Mario Pó
Pedro Miguel Romero-Campos
A. Fernando Almansa
Source :
Remote sensing, 13 (3), 1-20, ARCIMIS. Archivo Climatológico y Meteorológico Institucional (AEMET), Agencia Estatal de Meteorología (AEMET), Remote Sensing; Volume 13; Issue 3; Pages: 350, Remote Sensing, Vol 13, Iss 350, p 350 (2021)
Publication Year :
2021
Publisher :
Multidisciplinary Digital Publishing Institute, 2021.

Abstract

Precipitable water vapor retrievals are of major importance for assessing and understanding atmospheric radiative balance and solar radiation resources. On that basis, this study presents the first PWV values measured with a novel EKO MS-711 grating spectroradiometer from direct normal irradiance in the spectral range between 930 and 960 nm at the Izaña Observatory (IZO, Spain) between April and December 2019. The expanded uncertainty of PWV (UPWV) was theoretically evaluated using the Monte-Carlo method, obtaining an averaged value of 0.37 ± 0.11 mm. The estimated uncertainty presents a clear dependence on PWV. For PWV ≤ 5 mm (62% of the data), the mean UPWV is 0.31 ± 0.07 mm, while for PWV > 5 mm (38% of the data) is 0.47 ± 0.08 mm. In addition, the EKO PWV retrievals were comprehensively compared against the PWV measurements from several reference techniques available at IZO, including meteorological radiosondes, Global Navigation Satellite System (GNSS), CIMEL-AERONET sun photometer and Fourier Transform Infrared spectrometry (FTIR). The EKO PWV values closely align with the above mentioned different techniques, providing a mean bias and standard deviation of −0.30 ± 0.89 mm, 0.02 ± 0.68 mm, −0.57 ± 0.68 mm, and 0.33 ± 0.59 mm, with respect to the RS92, GNSS, FTIR and CIMEL-AERONET, respectively. According to the theoretical analysis, MB decreases when comparing values for PWV > 5 mm, leading to a PWV MB between −0.45 mm (EKO vs. FTIR), and 0.11 mm (EKO vs. CIMEL-AERONET). These results confirm that the EKO MS-711 spectroradiometer is precise enough to provide reliable PWV data on a routine basis and, as a result, can complement existing ground-based PWV observations. The implementation of PWV measurements in a spectroradiometer increases the capabilities of these types of instruments to simultaneously obtain key parameters used in certain applications such as monitoring solar power plants performance. This study has been performed thanks to regular funds from the State Meteorological Agency of Spain (AEMET) to the World Meteorological Organization (WMO) Commission for Instruments and Methods of Observations (CIMO) Izaña Testbed for Aerosols and Water Vapor Remote Sensing Instruments and the European Community Research Infrastructure Action under the FP7 ACTRIS grant, agreement no. 262254.

Details

Language :
English
ISSN :
20724292
Database :
OpenAIRE
Journal :
Remote sensing, 13 (3), 1-20, ARCIMIS. Archivo Climatológico y Meteorológico Institucional (AEMET), Agencia Estatal de Meteorología (AEMET), Remote Sensing; Volume 13; Issue 3; Pages: 350, Remote Sensing, Vol 13, Iss 350, p 350 (2021)
Accession number :
edsair.doi.dedup.....9adc762c74c2940797f195b12ad05b07