Back to Search Start Over

A loss measurement system in a test facility for high-current superconducting cables and wires

Authors :
H.H.J. ten Kate
B. ten Haken
L.J.M. van de Klundert
Wim S. J. Uijttewaal
A.J.M. Roovers
Faculty of Science and Technology
Energy, Materials and Systems
Source :
IEEE transactions on magnetics, 24(2, par), 1174-1177. IEEE
Publication Year :
1988
Publisher :
Institute of Electrical and Electronics Engineers (IEEE), 1988.

Abstract

The AC loss measurement system in the Twente test facility is operational. Preliminary results of the first loss measurements on a vacuum-welded conductor are presented. The Twente test facility is a high-current system in which superconductors can be tested up to 7 T and 25 kA. The loss measurements were done on a monolith conductor designed for TORE SUPRA, manufactured by Vacuumschmelze. >

Details

ISSN :
19410069 and 00189464
Volume :
24
Database :
OpenAIRE
Journal :
IEEE Transactions on Magnetics
Accession number :
edsair.doi.dedup.....9a940addc54c7f459cbedffd4b6fe362
Full Text :
https://doi.org/10.1109/20.11442