Back to Search
Start Over
Reduced-iodine-dose dual-energy coronary CT angiography: qualitative and quantitative comparison between virtual monochromatic and polychromatic CT images
- Source :
- European radiology, vol. 31, no. 9, pp. 7132-7142, European Radiology
- Publication Year :
- 2021
- Publisher :
- Springer Science and Business Media LLC, 2021.
-
Abstract
- Objectives To quantitatively evaluate the impact of virtual monochromatic images (VMI) on reduced-iodine-dose dual-energy coronary computed tomography angiography (CCTA) in terms of coronary lumen segmentation in vitro, and secondly to assess the image quality in vivo, compared with conventional CT obtained with regular iodine dose. Materials and methods A phantom simulating regular and reduced iodine injection was used to determine the accuracy and precision of lumen area segmentation for various VMI energy levels. We retrospectively included 203 patients from December 2017 to August 2018 (mean age, 51.7 ± 16.8 years) who underwent CCTA using either standard (group A, n = 103) or reduced (group B, n = 100) iodine doses. Conventional images (group A) were qualitatively and quantitatively compared with 55-keV VMI (group B). We recorded the location of venous catheters. Results In vitro, VMI outperformed conventional CT, with a segmentation accuracy of 0.998 vs. 1.684 mm2, respectively (p < 0.001), and a precision of 0.982 vs. 1.229 mm2, respectively (p < 0.001), in simulated overweight adult subjects. In vivo, the rate of diagnostic CCTA in groups A and B was 88.4% (n = 91/103) vs. 89% (n = 89/100), respectively, and noninferiority of protocol B was inferred. Contrast-to-noise ratios (CNR) of lumen versus fat and muscle were higher in group B (p < 0.001) and comparable for lumen versus calcium (p = 0.423). Venous catheters were more often placed on the forearm or hand in group B (p < 0.001). Conclusion In vitro, low-keV VMI improve vessel area segmentation. In vivo, low-keV VMI allows for a 40% iodine dose and injection rate reduction while maintaining diagnostic image quality and improves the CNR between lumen versus fat and muscle. Key Points • Dual-energy coronary CT angiography is becoming increasingly available and might help improve patient management. • Compared with regular-iodine-dose coronary CT angiography, reduced-iodine-dose dual-energy CT with low-keV monochromatic image reconstructions performed better in phantom-based vessel cross-sectional segmentation and proved to be noninferior in vivo. • Patients receiving reduced-iodine-dose dual-energy coronary CT angiography often had the venous catheter placed on the forearm or wrist without compromising image quality.
- Subjects :
- Adult
medicine.medical_specialty
Computed Tomography Angiography
Coronary vessels
Contrast Media
Lumen (anatomy)
Signal-To-Noise Ratio
030204 cardiovascular system & hematology
Phantoms, imaging
Imaging phantom
030218 nuclear medicine & medical imaging
Radiography, Dual-Energy Scanned Projection
03 medical and health sciences
0302 clinical medicine
Forearm
Dimensional measurement accuracy
medicine
Humans
Radiology, Nuclear Medicine and imaging
Aged
Retrospective Studies
Neuroradiology
Computed tomography angiography
Dose-Response Relationship, Drug
medicine.diagnostic_test
Iodine/administration & dosage
Middle Aged
Radiographic Image Interpretation, Computer-Assisted
Tomography, X-Ray Computed
Iodine
business.industry
Ultrasound
Interventional radiology
General Medicine
Catheter
medicine.anatomical_structure
Radiology
business
Cardiac
Subjects
Details
- ISSN :
- 14321084 and 09387994
- Volume :
- 31
- Database :
- OpenAIRE
- Journal :
- European Radiology
- Accession number :
- edsair.doi.dedup.....9a85d445ae1f9676090978488a9daeaf
- Full Text :
- https://doi.org/10.1007/s00330-021-07809-w