Back to Search
Start Over
Biomechanical influence of crown-to-implant ratio on stress distribution over internal hexagon short implant: 3-D finite element analysis with statistical test
- Source :
- Repositório Institucional da USP (Biblioteca Digital da Produção Intelectual), Universidade de São Paulo (USP), instacron:USP
- Publication Year :
- 2015
- Publisher :
- Elsevier BV, 2015.
-
Abstract
- The study of short implants is relevant to the biomechanics of dental implants, and research on crown increase has implications for the daily clinic. The aim of this study was to analyze the biomechanical interactions of a singular implant-supported prosthesis of different crown heights under vertical and oblique force, using the 3-D finite element method. Six 3-D models were designed with Invesalius 3.0, Rhinoceros 3D 4.0, and Solidworks 2010 software. Each model was constructed with a mandibular segment of bone block, including an implant supporting a screwed metal-ceramic crown. The crown height was set at 10, 12.5, and 15 mm. The applied force was 200 N (axial) and 100 N (oblique). We performed an ANOVA statistical test and Tukey tests; p0.05 was considered statistically significant. The increase of crown height did not influence the stress distribution on screw prosthetic (p0.05) under axial load. However, crown heights of 12.5 and 15 mm caused statistically significant damage to the stress distribution of screws and to the cortical bone (p0.001) under oblique load. High crown to implant (C/I) ratio harmed microstrain distribution on bone tissue under axial and oblique loads (p0.001). Crown increase was a possible deleterious factor to the screws and to the different regions of bone tissue.
- Subjects :
- Materials science
medicine.medical_treatment
Finite Element Analysis
Biomedical Engineering
Biophysics
Dentistry
Mandible
Bone tissue
medicine.disease_cause
Prosthesis
Crown (dentistry)
Weight-bearing
Weight-Bearing
stomatognathic system
medicine
Humans
Orthopedics and Sports Medicine
Dental Implants
business.industry
Rehabilitation
PRÓTESE SOBRE IMPLANTES ÓSSEOINTEGRADOS
Biomechanics
Oblique case
Models, Theoretical
stomatognathic diseases
medicine.anatomical_structure
Dental Prosthesis Design
Cortical bone
Dental Prosthesis, Implant-Supported
Stress, Mechanical
Implant
business
Subjects
Details
- ISSN :
- 00219290
- Volume :
- 48
- Database :
- OpenAIRE
- Journal :
- Journal of Biomechanics
- Accession number :
- edsair.doi.dedup.....9a59594467821e2a0eb60e4136b2bb6d
- Full Text :
- https://doi.org/10.1016/j.jbiomech.2014.10.021