Back to Search Start Over

Identification of repetitive atrial activation patterns in persistent atrial fibrillation by direct contact high-density electrogram mapping

Authors :
Ziad Zeidan
Michael Wolf
Jan De Pooter
Thomas Phlips
Maria Kyriakopoulou
Rene Tavernier
Yves Vandekerckhove
Teresa Strisciuglio
Milad El Haddad
Michelle Lycke
Mattias Duytschaever
Sébastien Knecht
Alexandre Almorad
Wolf, M.
Tavernier, R.
Zeidan, Z.
El Haddad, M.
Vandekerckhove, Y.
Pooter, J. D.
Phlips, T.
Strisciuglio, T.
Almorad, A.
Kyriakopoulou, M.
Lycke, M.
Duytschaever, M.
Knecht, S.
Source :
J Cardiovasc Electrophysiol
Publication Year :
2019

Abstract

Introduction Recent studies have characterized drivers in persistent atrial fibrillation using automated algorithm detection with panoramic endocardial mapping by means of basket catheters. We aimed to identify repetitive atrial activation patterns (RAAPs) during ongoing atrial fibrillation (AF) based upon automated annotation of unipolar electrograms (EGMs) recorded with a high-density regional endocardial contact mapping catheter. Methods In 14 persistent AF patients, high-resolution EGMs were recorded for 30 seconds at sequential PentaRay (Biosense Inc) positions covering the entire biatrial surface. All recordings were reviewed off-line with dedicated software allowing automated annotation of the local activation time of the unipolar fibrillatory EGMs (CARTOFINDER; Biosense Inc). RAAPs were defined as a consistent activation pattern (for ≥3 consecutive beats) of either focal activity with centrifugal spread (RAAPfocal ) or rotational activity across the PentaRay splines spanning the AF cycle length (RAAProtational ). Results A total of 498 PentaRay recordings were analyzed (35.6 ± 7.6 per patient). The number of PentaRay recordings displaying RAAP was 9.8 ± 3.1 per patient (range = 3-15), of which 2.4 ± 2.4 RAAProtational (range = 0-7), and 7.4 ± 4.4 RAAPfocal (range = 1-13). 77% of RAAPs portrayed focal firing. The median number of repetitions per 30 second recording was 11 (range = 3-225) per recording. RAAPs were observed both in the right atrium (RA) (35%) and left atrium (LA) (65%), with the majority being near the left PVs/appendage (35% of all RAAPs) and the superior vena cava/right appendage (23% of all RAAPs). Conclusion High-resolution, sequential endocardial EGM-based mapping allows identification of RAAPs in persistent AF. In our series, focal firing was the most frequently observed pattern.

Details

Language :
English
Database :
OpenAIRE
Journal :
J Cardiovasc Electrophysiol
Accession number :
edsair.doi.dedup.....995946d8166c236e31ac9e5f6e7870c2