Back to Search
Start Over
Investigation of shutter scan acquisition parameters in a prototype chest digital tomosynthesis system
- Source :
- Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics (AIFB). 57
- Publication Year :
- 2018
-
Abstract
- A shutter scan acquisition (SSA) method is proposed to reduce patient exposure dose in a chest digital tomosynthesis system. Projections obtained using the SSA constitute a combination of truncated and non-truncated projections. The truncated projections are images in which the lung field is set within a region-of-interest (ROI), and the non-truncated projections are full images in which the ROI is not set at all. We proposed a shutter weighting factor (SWF) as an acquisition parameter for SSA. We call the number of truncated projections divided by the number of non-truncated projections as SWF. We used a prototype CDT system and the LUNGMAN phantom with 8 and 10 mm lung nodules. 81 projections were obtained using SSA in five sets according to the SWFs. The image quality was quantified based on the contrast-to-noise ratio (CNR). We also calculated the figure of merit (FOM) to determine the proper acquisition parameters of the five sets. Both the CNR and FOM values of the 8 mm lung nodule in the selected ROI increased with increases of the SWF. However, the CNR value of the 10 mm lung nodule outside the ROI decreased with increases of the SWF, while the FOM value was maximized when the SWF was 3.05. We investigated the effect of the composition ratio of the truncated and non-truncated projections on the reconstructed images of the SSA based on the FOM values. In conclusion, we determined the proper SSA parameters in a prototype CDT system.
- Subjects :
- Quality Control
business.industry
Image quality
Biophysics
General Physics and Astronomy
General Medicine
Patient exposure
Thorax
Tomosynthesis
Imaging phantom
030218 nuclear medicine & medical imaging
Weighting
03 medical and health sciences
0302 clinical medicine
030220 oncology & carcinogenesis
Shutter
Image Processing, Computer-Assisted
Figure of merit
Radiology, Nuclear Medicine and imaging
Computer vision
Artificial intelligence
business
Lung field
Mathematics
Mammography
Subjects
Details
- ISSN :
- 1724191X
- Volume :
- 57
- Database :
- OpenAIRE
- Journal :
- Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics (AIFB)
- Accession number :
- edsair.doi.dedup.....991080dbbf830913fb00735744cfc3aa