Effects of Radiant Floor Heating Integrated with Natural Ventilation on Flow and Dispersion in a Newly Decorated Residence
- Source :
- International Journal of Environmental Research and Public Health; Volume 19; Issue 24; Pages: 16889
- Publication Year :
- 2022
-
Abstract
- To date, few studies have been conducted on the characteristics of flow and dispersion caused by indoor radiant floor heating integrated with natural ventilation. In this study, we employed reduced−scale numerical models validated by wind−tunnel experiments to investigate the influence of radiant floor heating integrated with natural ventilation on airflow, heat transfer, and pollutant dispersion within an isolated building. The Richardson number (Ri) was specified to characterize the interaction between the inflow inertia force and the buoyancy force caused by radiant floor heating. Several Ri cases from 0 to 26.65, coupled with cross− or single−sided ventilation, were considered. Model validation showed that the numerical model coupled with the RNG k-ε model was able to better predict the indoor buoyant flow and pollutant dispersion. The results showed that the similarity criterion of Ri equality should be first satisfied in order to study indoor mixed convection using the reduced−scale model, followed by Re−independence. For cross−ventilation, when Ri < 5.31, the incoming flow inertia force mainly dominates the indoor flow structure so that the ACH, indoor temperature, and pollutant distributions remain almost constant. When Ri > 5.31, the thermal buoyancy force becomes increasingly important, causing significant changes in indoor flow structures. However, for single−sided ventilation, when Ri > 5.31 and continues to increase, the buoyancy force mainly dominates the indoor flow structure, causing a significant increase in ACH, thus reducing the indoor average temperature and pollutant accumulation.
- Subjects :
- Heating
Hot Temperature
Health, Toxicology and Mutagenesis
Air Pollution, Indoor
Public Health, Environmental and Occupational Health
Temperature
Environmental Pollutants
Models, Theoretical
Ventilation
numerical simulation
radiant floor heating
natural ventilation
indoor air quality
pollutant dispersion