Back to Search
Start Over
Comparison of navigator-gated and breath-held image acquisition techniques for multi-echo quantitative dixon imaging of the liver in children and young adults
- Source :
- Abdominal radiology (New York). 44(6)
- Publication Year :
- 2019
-
Abstract
- Acquired over a breath hold, multi-echo Dixon (mDixon) magnetic resonance imaging (MRI) of the liver can be used to quantify proton density fat fraction (PDFF) and iron-related signal decay. However, young, obese, and co-morbid patients may have limited breath holding capacity and could benefit from a motion-robust mDixon acquisition. The purpose of this study was to compare hepatic PDFF and R2* values between navigator-gated and breath-held mDixon MRI acquisition techniques in children and young adults with suspected liver disease. This retrospective study was institutional review board-approved with a waiver of informed consent. Patients who underwent liver MRI with breath-held and navigator-gated mDixon sequences between January 2017 and July 2018 were included. One reviewer, blinded to sequence, measured PDFF and R2* on four images from each sequence. Another blinded reviewer graded respiratory motion (5-point Likert scale). Pearson correlation (r), Lin’s concordance coefficients (rc), and Bland–Altman analyses were used to assess agreement between techniques. Frequency of clinically limiting motion (score ≥ 3) was compared with Fisher’s exact test. Forty-two patients were included (15 female, 27 male; mean age: 15.7 ± 4.6 years). Mean PDFF and R2* were 16.6 ± 13.1% and 29.3 ± 4.7 s−1 (breath-held) versus 17.0 ± 13.2% and 29.6 ± 5.2 s−1 (navigator-gated). PDFF agreed almost perfectly between sequences (rc = 0.997, 95% CI 0.994–0.998; mean bias: 0.3%; 95% limits of agreement: − 2.4 to +1.7%), while R2* values correlated very strongly but with poor agreement (r = 0.837, rc = 0.832, 95% CI 0.716–0.910). Navigator-gated images exhibited significantly higher frequency of clinically limiting respiratory motion (88% vs. 48%, p = 0.0001). Despite greater respiratory motion artifact, a free-breathing navigator-gated mDixon sequence produces PDFF values with almost perfect agreement to a breath-held sequence.
- Subjects :
- Male
Adolescent
Urology
Concordance
Liver mri
030218 nuclear medicine & medical imaging
Breath Holding
03 medical and health sciences
Liver disease
Young Adult
0302 clinical medicine
Image Interpretation, Computer-Assisted
Medicine
Image acquisition
Humans
Radiology, Nuclear Medicine and imaging
Young adult
Retrospective Studies
Radiological and Ultrasound Technology
medicine.diagnostic_test
business.industry
Liver Diseases
Gastroenterology
Proton density fat fraction
Magnetic resonance imaging
medicine.disease
Magnetic Resonance Imaging
Exact test
030220 oncology & carcinogenesis
Female
business
Nuclear medicine
Artifacts
Subjects
Details
- ISSN :
- 23660058
- Volume :
- 44
- Issue :
- 6
- Database :
- OpenAIRE
- Journal :
- Abdominal radiology (New York)
- Accession number :
- edsair.doi.dedup.....988b02a4cce712094a6decf4e4ac3173