Back to Search
Start Over
Silver in situ hybridization (SISH) for determination of HER2 gene status in breast carcinoma: comparison with FISH and assessment of interobserver reproducibility
- Source :
- The American journal of surgical pathology. 34(6)
- Publication Year :
- 2010
-
Abstract
- The importance of HER2 status in breast cancer management has focused attention on the ability of clinical assays to correctly assign HER2 amplification status. There is no consensus as to the best method for assessing HER2 status. Disadvantages of fluorescence in situ hybridization (FISH) testing include longer time required for staining and scoring slides, requirements for specialized training and fluorescence microscopy, and loss of the signal due to quenching of the fluorescent dye. Silver-enhanced in situ hybridization (SISH) is a rapid fully automated assay providing permanently stained slides that are interpreted by conventional bright field microscopy which enables pathologists to evaluate slides within the context of tissue morphology. This study evaluates the concordance between SISH and FISH assays in determining the status of HER2 gene amplification in a cohort of 298 primary invasive breast carcinomas. Furthermore, we assessed in detail the variables contributing to interobserver interpretive reproducibility of HER2 SISH among 10 pathologists. HER2 was quantified using the ratio of HER2 to CHR17 signals using the conventional historical interpretation scale and also by the American Society of Clinical Oncology/College of American Pathologists reporting scheme. For SISH status determined by consensus among 10 pathologists, overall concordance between SISH and FISH was identified in 288 of 298 cases (96.6%) using the conventional Food and Drug Administration approved criteria. Overall agreement was observed in 282 of 285 cases (98.9%) using the American Society of Clinical Oncology/College of American Pathologists result reporting scheme (with equivocal cases removed). In conclusion, SISH represents a novel approach for the determination of HER2 status in breast cancer. The overall concordance between SISH and FISH is excellent, and the interpretation of SISH results by pathologists is most reproducible using the HER2/CHR17 ratio.
- Subjects :
- medicine.medical_specialty
Pathology
Concordance
Interobserver reproducibility
Context (language use)
Breast Neoplasms
Biology
Pathology and Forensic Medicine
Breast cancer
medicine
HER2 Amplification
Humans
skin and connective tissue diseases
In Situ Hybridization
In Situ Hybridization, Fluorescence
Observer Variation
medicine.diagnostic_test
Reproducibility of Results
Silver Compounds
Genes, erbB-2
medicine.disease
Fish
Surgery
Female
Radiology
Anatomy
Breast carcinoma
Nucleic Acid Amplification Techniques
Fluorescence in situ hybridization
Subjects
Details
- ISSN :
- 15320979
- Volume :
- 34
- Issue :
- 6
- Database :
- OpenAIRE
- Journal :
- The American journal of surgical pathology
- Accession number :
- edsair.doi.dedup.....97a93d986854f7522f7571165af6bd46