Electrochemical immunosensor for detection of CA 15-3 biomarker in point-of-care
- Source :
- Repositório Científico de Acesso Aberto de Portugal, Repositório Científico de Acesso Aberto de Portugal (RCAAP), instacron:RCAAP, Sensing and Bio-Sensing Research, Vol 33, Iss, Pp 100445-(2021)
- Publication Year :
- 2021
- Publisher :
- Elsevier BV, 2021.
-
Abstract
- This work reports the development of a simple and rapid electrochemical immunosensor for the determination of breast cancer biomarker Cancer Antigen 153 (CA153). Disposable and cost-effective chips, consisting of gold screen-printed electrodes (AuSPEs), were used to develop the portable electrochemical devices for monitoring the biomarker in point-of-care (PoC), under clinical context. The biosensor preparation consisted of two simple steps. First, a self-assembled monolayer (SAM) of mercaptosuccinic acid (MSA) was formed at the AuSPE surface. Then, the CA153 antibody was covalently bound to the carboxylic groups standing at the electrode surface using EDC/NHS chemistry. The performance of the developed immunosensor was evaluated by assessing the sensor sensitivity, linear response interval, selectivity and detection limit (LOD). The developed immunosensor provided a wide linear concentration range (from 1.0 to 1000UmL1) and low detection levels were achieved (LOD of 0.95UmL1), enabling the sensitive detection of the cancer biomarker at clinically relevant levels, using square wave voltammetry (SWV) as electroanalytical technique. Moreover, selectivity studies performed against other cancer biomarkers (CA 125 and CA 199) revealed that the antibody has high selectivity for CA15-3 antigen. The immunosensor was applied to the quantification of CA15-3 in artificial serum samples with satisfactory results.<br />This research had the financial support of FCT (Fundação para a Ciência e Tecnologia) and co-financed by the European Union (FEDER funds) under the Partnership Agreement PT2020, Research Grants Pest-C/QUI/UIDB/00081/2020 (CIQUP) and NORTE-01-0247-FEDER-017834 (project RamSERS). J.A. Ribeiro (ref. SFRH/BPD/105395/2014) and C.M. Pereira (ref. SFRH/BSAB/150320/2019) acknowledge FCT under the QREN – POPH – Advanced Training, subsidized by European Union and national MEC funds.<br />info:eu-repo/semantics/publishedVersion
- Subjects :
- Library science
02 engineering and technology
Immunosensor
010402 general chemistry
01 natural sciences
Point-of-care (PoC) analysis
Political science
media_common.cataloged_instance
Electrochemical biosensor
Electrical and Electronic Engineering
European union
media_common
Science & Technology
Cancer biomarker
Screen-printed electrode (SPE)
Engineering (General). Civil engineering (General)
021001 nanoscience & nanotechnology
0104 chemical sciences
3. Good health
Electronic, Optical and Magnetic Materials
Signal Processing
TA1-2040
CA 15-3
0210 nano-technology
Biotechnology
Subjects
Details
- Language :
- English
- Database :
- OpenAIRE
- Journal :
- Repositório Científico de Acesso Aberto de Portugal, Repositório Científico de Acesso Aberto de Portugal (RCAAP), instacron:RCAAP, Sensing and Bio-Sensing Research, Vol 33, Iss, Pp 100445-(2021)
- Accession number :
- edsair.doi.dedup.....9786864637c5dc8a4a6b51639a98d137