Back to Search
Start Over
Inter- and intrarater reliability of goniometry and hand held dynamometry for patients with subacromial impingement syndrome
- Source :
- Journal of Exercise Rehabilitation
- Publication Year :
- 2017
- Publisher :
- Korean Society of Exercise Rehabilitation, 2017.
-
Abstract
- The purpose of this study was to examine the intra- and interrater reliability of measuring shoulder range of motion (ROM) and strength among patients diagnosed with subacromial impingement syndrome (SAIS). Twenty-five patients (14 female patients; mean age, 60.4± 7.84 years) diagnosed with SAIS were assessed to determine the intrarater reliability for glenohumeral ROM. Twenty-five patients (16 female patients; mean age, 60.4± 7.80 years) and 76 asymptomatic volunteers (52 female volunteers; mean age, 29.4± 14.1 years) were assessed for interrater reliability. Dependent variables were active shoulder ROM and isometric strength. Intrarater reliability was fair-to-excellent for the SAIS patients (intraclass correlation coefficient [ICC], 0.52-0.97; standard error of measurement [SEM], 4.4°-9.9° N; coefficient of variation [CV], 7.1%-44.9%). Based on the ICC, 11 of 12 parameters (92%) displayed an excellent reliability (ICC> 0.75). The interrater reliability showed fair-to-excellent results (SAIS patients: ICC, 0.13-0.98; SEM, 2.3°-8.8°; CV, 3.6%-37.0%; controls: ICC, 0.11-0.96; SEM, 3.0°-35.4°; CV, 5.6%-26.4%). In accordance with the intrarater reliability, glenohumeral adduction ROM was the only parameter with an ICC below 0.75 for both samples. Painful shoulder ROM in the SAIS patients showed no influence on the quality of reliability for measurement. Therefore, these protocols should be considered reliable assessment techniques in the prevention, diagnosis, and treatment of painful shoulder conditions such as SAIS.
- Subjects :
- 030222 orthopedics
medicine.medical_specialty
Shoulder
Intraclass correlation
business.industry
Coefficient of variation
Physical Therapy, Sports Therapy and Rehabilitation
030229 sport sciences
Intra-rater reliability
Isometric exercise
Reliability
Asymptomatic
Goniometry
03 medical and health sciences
Inter-rater reliability
0302 clinical medicine
medicine
Physical therapy
Orthopedics and Sports Medicine
Original Article
Hand-held dynamometry
medicine.symptom
Range of motion
business
Reliability (statistics)
Subjects
Details
- Language :
- English
- ISSN :
- 22881778 and 2288176X
- Volume :
- 13
- Issue :
- 6
- Database :
- OpenAIRE
- Journal :
- Journal of Exercise Rehabilitation
- Accession number :
- edsair.doi.dedup.....97395ddfe673e5429b5cbb985d23dcd6