Back to Search
Start Over
Improving Patient Safety: Implementing Dose Monitoring Software in Fluoroscopically Guided Interventions
- Source :
- Journal of Vascular and Interventional Radiology. 26:1699-1709
- Publication Year :
- 2015
- Publisher :
- Elsevier BV, 2015.
-
Abstract
- To assess whether dose monitoring software can be successfully implemented in fluoroscopically guided interventions and to provide dose data based on levels of complexity.After launching the software (DoseWatch; GE Healthcare Systems, Buc, France), data were collected for 6 months and analyzed by means of kerma-area product (KAP; Gy/cm(2)), cumulative air kerma (KA,R; Gy), and fluoroscopic time (minutes). Data analysis was executed by level of complexity as graded by the operators. Complexity grading was based on factors such as tortuosity and calcification of vessel, variant anatomy, and patient cooperation.The software successfully transferred dose data of 357 fluoroscopically guided procedures. KAP was 0.238-400 Gy/cm(2) with mean, median, and 75th percentile values of 46.0 Gy/cm(2), 163.2 Gy/cm(2), and 541.1 Gy/cm(2) (KA,R, 0.013-4.1 Gy; mean, median, 75th percentile, 0.48 Gy, 0.97 Gy, 3.98 Gy). Highest dose values were seen in transarterial chemoembolization (KAP mean, median, 75th percentile, 229.5 Gy/cm(2), 216.4 Gy/cm(2), 299.9 Gy/cm(2); KA,R mean, median, 75th percentile, 1.9 Gy, 1.2 Gy, 1.7 Gy). Analysis revealed that the level of complexity strongly correlated with KAP (r = 0.88; P.001) whereas there was no direct correlation of KAP and fluoroscopy time. During the same intervention, KA,R and fluoroscopy time increased with level of complexity, but the correlation was not statistically significant.Implementation of dose monitoring software in fluoroscopically guided interventions can be successfully accomplished, and it facilitates data comparison.
- Subjects :
- Adult
Male
Percentile
Software Validation
Radiation Dosage
Radiography, Interventional
Sensitivity and Specificity
Patient Cooperation
Young Adult
Kerma
Radiation Protection
Radiation Monitoring
Monitoring, Intraoperative
Humans
Medicine
Fluoroscopy
Radiology, Nuclear Medicine and imaging
Aged
Aged, 80 and over
medicine.diagnostic_test
business.industry
Reproducibility of Results
Middle Aged
Dose monitoring
Surgery, Computer-Assisted
Female
Patient Safety
Cardiology and Cardiovascular Medicine
business
Nuclear medicine
Software
Switzerland
Healthcare system
Subjects
Details
- ISSN :
- 10510443
- Volume :
- 26
- Database :
- OpenAIRE
- Journal :
- Journal of Vascular and Interventional Radiology
- Accession number :
- edsair.doi.dedup.....962b5351d11809a8531e507fe3c7510d