Back to Search Start Over

Optimization of Airborne Endotoxin Exposure Assessment: Effects of Filter Type, Transport Conditions, Extraction Solutions, and Storage of Samples and Extracts

Authors :
Spaan, S.
Heederik, D.J.J.
Thorne, P.S.
Wouters, I.M.
Risk Assessment of Toxic and Immunomodulatory Agents
Dep IRAS
Source :
Applied and Environmental Microbiology, 73(19), 6134. American Society for Microbiology
Publication Year :
2007
Publisher :
American Society for Microbiology, 2007.

Abstract

Endotoxin exposure occurs in homes and occupational environments and is known to cause adverse health effects. In order to compare results from different studies and establish standards, airborne endotoxin exposures should be assessed using standardized methods. Although the European Committee for Standardization (CEN) developed guidelines for endotoxin exposure assessment, these leave room for individual interpretation. The influence of methods of sampling, extraction, and analysis has never been investigated in a full experimental design. Thus, we sought to fully elucidate the importance of all facets of endotoxin assessment. Inhalable dust samples collected simultaneously were used to investigate the effects on and interactions with airborne endotoxin concentration in two working environments of filter type (glass fiber or Teflon), transport conditions (with/without desiccant), sample storage (-20 or 4°C), extraction solution (pyrogen-free water [PFW] or PFW plus 0.05% Tween 20), extract storage (-20 or 4°C), and assay solution (PFW or PFW plus 0.05% Tween 20). Four hundred samples were collected and randomly distributed over the 20 combinations of treatments. There were no differences found for transport conditions and storage temperature of extracts. Also, no interactions between study variables existed. Sampling on glass-fiber filters, storage of samples in the freezer, and extraction in PFW plus 0.05% Tween 20 resulted in 1.3-, 1.1-, and 2.1-fold-higher estimated endotoxin concentrations, respectively. Use of PFW plus 0.05% Tween 20 in the assay solution had an additive effect. Thus, this study investigated gaps in the CEN protocol and provides data with which to fully specify a protocol for standardization of endotoxin exposure assessment. Copyright © 2007, American Society for Microbiology. All Rights Reserved.

Details

ISSN :
10985336 and 00992240
Volume :
73
Database :
OpenAIRE
Journal :
Applied and Environmental Microbiology
Accession number :
edsair.doi.dedup.....96189218d7b2b53a7f43b1c969d59c72
Full Text :
https://doi.org/10.1128/aem.00851-07