Abstract
- Study Design Retrospective comparative study. Objective To evaluate the accuracy of percutaneous pedicle screw (PPS) placement and intraoperative imaging time using dual fluoroscopy units and their differences between surgeons with more versus less experience. Methods One hundred sixty-one patients who underwent lumbar fusion surgery were divided into two groups, A ( n = 74) and B ( n = 87), based on the performing surgeon's experience. The accuracy of PPS placement and radiation time for PPS insertion were compared. PPSs were inserted with classic technique under the assistance of dual fluoroscopy units placed in two planes. The breach definition of PPS misplacement was based on postoperative computed tomography (grade I: no breach; grade II: Results Of 658 PPSs, only 21 screws were misplaced. The breach rates of groups A and B were 3.3% (grade II: 3.4%, grade III: 0%) and 3.1% (grade II: 2.6%, grade III: 0.6%; p = 0.91). One patient in grade III misplacement had a transient symptom of leg numbness. Median radiation exposure time during PPS insertion was 25 seconds and 51 seconds, respectively ( p < 0.01). Conclusions Without using an expensive imaging support system, the classic technique of PPS insertion using dual fluoroscopy units in the lumbar and sacral spine is fairly accurate and provides good clinical outcomes, even among surgeons lacking experience.
- Subjects :
- medicine.medical_specialty
Percutaneous
education
dual fluoroscopy units
Computed tomography
radiation exposure
Article
03 medical and health sciences
0302 clinical medicine
Lumbar
percutaneous pedicle screw
medicine
Fluoroscopy
Orthopedics and Sports Medicine
Pedicle screw
Intraoperative imaging
health care economics and organizations
030222 orthopedics
surgeon experience
medicine.diagnostic_test
accuracy
business.industry
Surgery
Radiation exposure
Support system
Neurology (clinical)
business
030217 neurology & neurosurgery
Subjects
Details
- Language :
- English
- ISSN :
- 21925690 and 21925682
- Volume :
- 6
- Issue :
- 4
- Database :
- OpenAIRE
- Journal :
- Global Spine Journal
- Accession number :
- edsair.doi.dedup.....960c32a822500e164e61618891761038