Back to Search Start Over

Digital pulse-timing technique for the neutron detector array NEDA

Authors :
V. Modamio
G. Jaworski
A. Triossi
Marek Moszynski
A. Gadea
T. Hüyük
S. Erturk
Johan Nyberg
Vicente González
Enrique Sanchis
J. J. Valiente-Dobón
A. Di Nitto
J. Kownacki
M. Palacz
J. Egea
J. Agramunt Ros
G. de Angelis
M. N. Erduran
R. Wadsworth
P. A. Söderström
0-Belirlenecek
Grand Accélérateur National d'Ions Lourds (GANIL)
Commissariat à l'énergie atomique et aux énergies alternatives (CEA)-Institut National de Physique Nucléaire et de Physique des Particules du CNRS (IN2P3)-Centre National de la Recherche Scientifique (CNRS)
Triossi, Andrea -- 0000-0001-5140-9154
Millan, Vicente Gonzalez -- 0000-0001-6014-2586
Jaworski, Grzegorz -- 0000-0003-2241-0329
Gadea, Andres -- 0000-0002-4233-1970
Di Nitto, Antonio -- 0000-0002-9319-366X
SANCHIS, ENRIQUE -- 0000-0002-9689-9131
Huyuk, Tayfun -- 0000-0003-0597-9767
Soderstrom, Par-Anders -- 0000-0002-9504-2814
de France, Gilles -- 0000-0002-7439-1759
[Modamio, V. -- Valiente-Dobon, J. J. -- Triossi, A. -- de Angelis, G.] Ist Nazl Fis Nucl, Lab Nazl Legnaro, I-35020 Legnaro, Italy -- [Jaworski, G.] Warsaw Univ Technol, Fac Phys, PL-00662 Warsaw, Poland -- [Jaworski, G. -- Kownacki, J. -- Palacz, M.] Univ Warsaw, Heavy Ion Lab, PL-02093 Warsaw, Poland -- [Hueyuek, T. -- Egea, J. -- Agramunt Ros, J. -- Gadea, A.] Univ Valencia, CSIC, Inst Fis Corpuscular, E-46980 Valencia, Spain -- [Egea, J. -- Gonzalez, V. -- Sanchis, E.] Univ Valencia, Dept Elect Engn, E-46100 Burjassot, Spain -- [Di Nitto, A.] Johannes Gutenberg Univ Mainz, D-55099 Mainz, Germany -- [Soederstroem, P. -A.] RIKEN, Nishina Ctr, Wako, Saitama 3510198, Japan -- [de France, G.] CEA, GANIL, DSAM, F-14076 Caen, France -- [de France, G.] IN2P3, CNRS, F-14076 Caen, France -- [Erduran, M. N.] Istanbul Sabahattin Zaim Univ, Fac Engn & Nat Sci, TR-34303 Cerrahpasa, Turkey -- [Erturk, S.] Nigde Univ, Fen Edebiyat Falkultesi, Fiz Bolumu, TR-51240 Nigde, Turkey -- [Moszynski, M.] Natl Ctr Nucl Res, PL-05400 Otwock, Poland -- [Nyberg, J.] Uppsala Univ, Dept Phys & Astron, SE-75120 Uppsala, Sweden -- [Wadsworthm, R.] Univ York, Dept Phys, York YO1 5DD, N Yorkshire, England
Modamio, V.
Valiente-Dobon, J. J.
Jaworski, G.
Huyuk, T.
Triossi, A.
Egea, J.
Di Nitto, A.
Soderstrom, P. -A.
Agramunt Ros, J.
De Angelis, G.
De France, G.
Erduran, M. N.
Erturk, S.
Gadea, A.
Gonzalez, V.
Kownacki, J.
Moszynski, M.
Nyberg, J.
Palacz, M.
Sanchis, E.
Wadsworth, R.
Source :
Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2015, 775, pp.71-76. ⟨10.1016/j.nima.2014.12.002⟩, Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, Elsevier, 2015, 775, pp.71-76. ⟨10.1016/j.nima.2014.12.002⟩
Publication Year :
2015
Publisher :
Elsevier BV, 2015.

Abstract

WOS: 000348040900011<br />A new digital pulse-timing algorithm, to be used with the future neutron detector array NEDA, has been developed and tested. The time resolution of four 5 in diameter photomultiplier tubes (XP4512, R4144, R11833-100, and ET9390-kb), coupled to a cylindrical 5 in by 5 in BC501A liquict scintillator detector was measured by employing digital sampling electronics and a constant fraction discriminator (CFD) algorithm. The zero crossing of the CM algorithm was obtained with a cubic spline interpolation, which was continuous up to the second derivative. The performance of the algorithm was studied at sampling rates of 500 MS/s and 200 MS/s. The time resolution obtained with the digital electronics was compared to the values acquired with a standard analog CFD. The result of this comparison shows that the time resolution from the analog and the digital measurements at 500 MS/s and at 200 MS/s are within 15% for all the tested photomultiplier tubes. (C) 2014 Elsevier B.V. All rights reserved.<br />Generalitat Valenciana, Spain [PROMETEO/2010/101, PROMETEO/2014/019]; MINECO, Spain [AIC-D-2011-0746, FPA2011-29854, FPA2012-33560]; STFC, UK; Swedish Research Council; Science and Technology Facilities Council [ST/L005727/1, ST/L005735/1, ST/J000124/1]<br />Work partially supported by the Generalitat Valenciana, Spain, under grant PROMETEO/2010/101 and PROMETEO/2014/019, by MINECO, Spain, under grants AIC-D-2011-0746, FPA2011-29854 and FPA2012-33560, by the STFC, UK and by the Swedish Research Council.

Details

ISSN :
01689002 and 18729576
Volume :
775
Database :
OpenAIRE
Journal :
Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Accession number :
edsair.doi.dedup.....96012568d971b3f6971d97ca08d5ef91
Full Text :
https://doi.org/10.1016/j.nima.2014.12.002