Back to Search Start Over

Radiation-Induced Degradation Analysis and Reliability Modeling of COTS ADCs for Space-Borne Miniature Fiber-Optic Gyroscopes

Authors :
Jing Jin
Kun Ma
Enrico Zio
Linghai Kong
Jiliang He
Xiaowei Wang
Ningfang Song
Beihang University (BUAA)
Centre de recherche sur les Risques et les Crises (CRC)
MINES ParisTech - École nationale supérieure des mines de Paris
Université Paris sciences et lettres (PSL)-Université Paris sciences et lettres (PSL)
Politecnico di Milano [Milan] (POLIMI)
Kyung Hee University (KHU)
Tsinghua University [Beijing] (THU)
City University of Hong Kong [Hong Kong] (CUHK)
Wuhan University [China]
Source :
IEEE Transactions on Instrumentation and Measurement, IEEE Transactions on Instrumentation and Measurement, Institute of Electrical and Electronics Engineers, 2021, 70, pp.1-8. ⟨10.1109/TIM.2021.3054419⟩
Publication Year :
2021
Publisher :
Institute of Electrical and Electronics Engineers (IEEE), 2021.

Abstract

Respecting the requirements of lightweight, small size, low power consumption and especially low cost, commercial off-the-shelf (COTS) analog-to-digital converters (ADCs) are gradually being used to replace specifically designed aerospace -grade ones in space-borne miniature interferometric fiber-optic gyroscopes (IFOGs). However, the total ionizing dose (TID) effect of $\gamma $ -ray radiation in the space environment may cause the damage of COTS ADCs, and lead to performance degradation and even the failure. In order to measure the safety of COTS ADCs in IFOGs under the TID effect, the radiation-induced degradation model and the corresponding reliability model are proposed in this work. First of all, the relationship between the degradation of COTS ADCs and the IFOG’s angular random walk (ARW) is deduced. Then, a radiation accelerated test is designed and performed, with a real-time, dynamic data acquisition method based on the first-input-first-output (FIFO) memories to determine the degradation of COTS ADCs. Finally, a degradation path model is established based on the degradation data, and the reliability of COTS ADCs used for space-borne IFOGs is further obtained by using the Monte Carlo method. An engineering application is introduced to show the effectiveness of the proposed model, and the results show that the reliability of the experimental COTS ADCs makes them usable for the space-borne miniature IFOGs in low-earth orbit (LEO) and geostationary earth orbit (GEO) space missions.

Details

ISSN :
15579662 and 00189456
Volume :
70
Database :
OpenAIRE
Journal :
IEEE Transactions on Instrumentation and Measurement
Accession number :
edsair.doi.dedup.....95289c8ca18762f5420566e58f71296b
Full Text :
https://doi.org/10.1109/tim.2021.3054419