Back to Search
Start Over
Paper-based potentiometric sensing devices modified with chemically reduced graphene oxide (CRGO) for trace level determination of pholcodine (opiate derivative drug)
- Source :
- RSC advances. 11(20)
- Publication Year :
- 2021
-
Abstract
- Robust, reliable and cost-effective paper-based analytical device for potentiometric pholcodine (opiate derivative drug) ion sensing has been prepared and characterized. A printed pholcodinium (PHL)2+/5-nitrobarbiturate (NB)− ion-association complex as a sensory material-based all-solid-state ion-selective electrode (ISE) on a chemically reduced graphene oxide (CRGO) solid-contact, and a printed all-solid-state Ag/AgCl reference electrode, has been combined on a hydrophobic paper substrate coated with fluorinated alkyl silane (CF3(CF2)7CH2CH2SiCl3, CF10). The sensors revealed a potentiometric slope of 28.7 ± 0.3 mV dec−1 (R2 = 0.9998) over a linear range starting from 2.0 × 10−7 M to 1.0 × 10−2 M and a detection limit of 0.04 μg mL−1. The repeatability and stability of the pholcodine paper-based sensor was found to be 2.32%. The RSD% (n = 6) was found to be 2.67% when using five different paper-based sensors. The sensor revealed an excellent selectivity towards PHL over dextromethorphan, codeine, ephedrine, carbinoxamine, caffeine, ketamine, and K+, Na+ and Ca2+ ions. It showed a good recovery (94–104%) for the determination of PHL in different artificial serum samples. The presented paper-based analytical device was successfully introduced for PHL determination in different pharmaceutical formulations (i.e. syrups and suspensions) containing pholcodine. The current work can be considered as a promising possible analytical tool to obtain cost-effective and disposable paper-based potentiometric sensing devices. These devices can be potentially manufacturable at large scales in pharmaceutical, clinical and forensic applications for opiate drug assessment.
- Subjects :
- Pholcodine
chemistry.chemical_classification
Detection limit
Materials science
General Chemical Engineering
010401 analytical chemistry
Potentiometric titration
02 engineering and technology
General Chemistry
021001 nanoscience & nanotechnology
01 natural sciences
Reference electrode
0104 chemical sciences
Linear range
chemistry
Electrode
medicine
Carbinoxamine
0210 nano-technology
Alkyl
Nuclear chemistry
medicine.drug
Subjects
Details
- ISSN :
- 20462069
- Volume :
- 11
- Issue :
- 20
- Database :
- OpenAIRE
- Journal :
- RSC advances
- Accession number :
- edsair.doi.dedup.....94d1cc3de95c9ed9f0488bc6bf8f5fdb