Back to Search
Start Over
Inverse calibration free fs-LIBS of copper-based alloys
- Source :
- Zeitschrift für physikalische Chemie (Münch., 1991) 230 (2016): 1201–1217. doi:10.1515/zpch-2015-0704, info:cnr-pdr/source/autori:Smaldone A.; De Bonis A.; Galasso A.; Guarnaccio A.; Santagata A.; Teghil R./titolo:Inverse calibration free fs-LIBS of copper-based alloys/doi:10.1515%2Fzpch-2015-0704/rivista:Zeitschrift für physikalische Chemie (Münch., 1991)/anno:2016/pagina_da:1201/pagina_a:1217/intervallo_pagine:1201–1217/volume:230
- Publication Year :
- 2016
- Publisher :
- Oldenbourg., München, Germania, 2016.
-
Abstract
- In this work the analysis by Laser Induced Breakdown Spectroscopy (LIBS) technique of copper-based alloys having different composition and performed with fs laser pulses is presented. A Nd:Glass laser (Twinkle Light Conversion, λ = 527 nm at 250 fs) and a set of bronze and brass certified standards were used. The inverse Calibration-Free method (inverse CF-LIBS) was applied for estimating the temperature of the fs laser induced plasma in order to achieve quantitative elemental analysis of such materials. This approach strengthens the hypothesis that, through the assessment of the plasma temperature occurring in fs-LIBS, straightforward and reliable analytical data can be provided. With this aim the capability of the here adopted inverse CF-LIBS method, which is based on the fulfilment of the Local Thermodynamic Equilibrium (LTE) condition, for an indirect determination of the species excitation temperature, is shown. It is reported that the estimated temperatures occurring during the process provide a good figure of merit between the certified and the experimentally determined composition of the bronze and brass materials, here employed, although further correction procedure, like the use of calibration curves, can be demanded. The reported results demonstrate that the inverse CF-LIBS method can be applied when fs laser pulses are used even though the plasma properties could be affected by the matrix effects restricting its full employment to unknown samples provided that a certified standard having similar composition is available.
- Subjects :
- Materials science
Inverse calibration
010401 analytical chemistry
Metallurgy
Analytical chemistry
chemistry.chemical_element
010501 environmental sciences
01 natural sciences
Copper
0104 chemical sciences
chemistry
Copper-based-alloys
Emission spectroscopy
Fs-LIBS
Inverse calibration free
Emission spectrum
Physical and Theoretical Chemistry
0105 earth and related environmental sciences
Subjects
Details
- Language :
- English
- Database :
- OpenAIRE
- Journal :
- Zeitschrift für physikalische Chemie (Münch., 1991) 230 (2016): 1201–1217. doi:10.1515/zpch-2015-0704, info:cnr-pdr/source/autori:Smaldone A.; De Bonis A.; Galasso A.; Guarnaccio A.; Santagata A.; Teghil R./titolo:Inverse calibration free fs-LIBS of copper-based alloys/doi:10.1515%2Fzpch-2015-0704/rivista:Zeitschrift für physikalische Chemie (Münch., 1991)/anno:2016/pagina_da:1201/pagina_a:1217/intervallo_pagine:1201–1217/volume:230
- Accession number :
- edsair.doi.dedup.....94d1aca29c828f762cfd990037f54832
- Full Text :
- https://doi.org/10.1515/zpch-2015-0704