Back to Search Start Over

Evaluation of Posterolateral Rotatory Knee Instability Using the Dial Test According to Tibial Positioning

Evaluation of Posterolateral Rotatory Knee Instability Using the Dial Test According to Tibial Positioning

Authors :
Young-Bok Jung
Chang-Hyun Nam
Ho-Joong Jung
Yong Seuk Lee
Source :
Arthroscopy: The Journal of Arthroscopic & Related Surgery. 25:257-261
Publication Year :
2009
Publisher :
Elsevier BV, 2009.

Abstract

This study examined the effect of the anteroposterior (AP) direction force on the tibial external rotation of a posterior cruciate ligament (PCL)/posterolateral corner (PLC)-deficient knee in a clinical setting.Between December 2006 and December 2007, 21 patients with a PCL-PLC injury were assessed using a dial test. The thigh-foot angle (TFA) and patella-tubercle angle (PTA) were measured with an external rotation stress applied to the tibia at both 30 degrees and 90 degrees of knee flexion in 2 different positions (reduced and posterior subluxed). The test was performed with the patient in the supine position and with an AP force applied to the tibia by an assistant. To reduce intra- and interobserver bias, the measurements were taken twice by 2 orthopaedic surgeons for all patients.In the subluxed position, the mean side-to-side differences in the TFA at 30 degrees and 90 degrees knee flexion were 12.6 degrees +/- 2.0 degrees and 12.3 degrees +/- 1.4 degrees , respectively. In the reduced position, the mean side-to-side differences in the TFA at 30 degrees and 90 degrees knee flexion were 18.4 degrees +/- 1.4 degrees and 18.5 degrees +/- 1.5 degrees , respectively. In the subluxed position, the mean side-to-side differences in the PTA at 30 degrees and 90 degrees knee flexion were 9.1 degrees +/- 0.8 degrees and 9.0 degrees +/- 0.7 degrees , respectively. In the reduced position, the mean side-to-side differences in the PTA at 30 degrees and 90 degrees knee flexion were 13.3 degrees +/- 0.6 degrees and 13.2 degrees +/- 0.6 degrees , respectively.The reduction of a posteriorly subluxed knee increased the tibial external rotation (TFA and PTA) during the dial test of combined PCL-PLC injuries in a clinical setting. The accuracy of the dial test may help present surgeons from missing a combined PLC injury that should be corrected in a PCL deficient knee.Level I, testing of previously developed diagnostic criteria in series of consecutive patients.

Details

ISSN :
07498063
Volume :
25
Database :
OpenAIRE
Journal :
Arthroscopy: The Journal of Arthroscopic & Related Surgery
Accession number :
edsair.doi.dedup.....93b5e1b2adbf29ae5d465c255da8cdf5
Full Text :
https://doi.org/10.1016/j.arthro.2008.10.007