Back to Search
Start Over
Assessment of the flow field in the heartmate 3 using three-dimensional particle tracking velocimetry and comparison to computational fluid dynamics
- Publication Year :
- 2020
-
Abstract
- Flow fields in rotary blood pumps (RBPs) have a significant influence on hemocompatibility. Because flow characteristics vary with flow rate, different operating conditions play a role. Furthermore, turbulence is crucial in the evaluation of blood damage potential, but the level of turbulence in implantable RBPs is still unknown. In this study, we addressed both research aspects and for the first time measured turbulent flow fields in the HeartMate 3 (HM3) at different operating flows. The averaged, three-dimensional velocity field including fluctuating velocity components in a HM3 with a transparent lower housing was measured using three-dimensional particle tracking velocimetry (3D-PTV). In vitro results were compared with computational fluid dynamic (CFD) simulations for two flow cases, representing the lower and upper physiologic flow range (2.7 and 5.7 L/min), using two different turbulence models that account for fluctuating velocity fields: the k-ω shear stress transport and the Reynolds stress model (RSM). The measurements revealed higher mean and turbulent kinetic energies (TKEs) for the low-flow condition especially within the gap beneath the impeller. Computed mean fields agree well with 3D-PTV for both models, but the RSM predicts the TKE levels better than the k-ω model. Computational fluid dynamic results further show wall shear stresses higher than 150 Pa, a commonly used damage threshold, in the bottom gap for the lower flow condition. In conclusion, the low-flow condition was found to be more prone to blood damage. Furthermore, CFD predictions for turbulence must be carefully experimentally validated.
- Subjects :
- Biomedical Engineering
Biophysics
2204 Biomedical Engineering
Bioengineering
610 Medicine & health
Reynolds stress
030204 cardiovascular system & hematology
Computational fluid dynamics
10052 Institute of Physiology
Biomaterials
03 medical and health sciences
Impeller
0302 clinical medicine
Particle tracking velocimetry
Shear stress
Humans
Computer Simulation
10220 Clinic for Surgery
1502 Bioengineering
Turbulence
business.industry
2502 Biomaterials
Models, Cardiovascular
General Medicine
Mechanics
Volumetric flow rate
030228 respiratory system
Flow (mathematics)
Hydrodynamics
570 Life sciences
biology
Heart-Assist Devices
Stress, Mechanical
Rheology
business
Blood Flow Velocity
1304 Biophysics
Subjects
Details
- Language :
- English
- Database :
- OpenAIRE
- Accession number :
- edsair.doi.dedup.....934a785b414ce1972f77a44c337e59df
- Full Text :
- https://doi.org/10.5167/uzh-175878