Back to Search Start Over

Eksperimentalna in-vitro razgradnja koštanog cementa pomoću ultrazvučnog pulzirajućeg mlaza vode za potrebe revizijske artroplastike

Authors :
Aleksandar Sedmak
Peter Monka
Dražan Kozak
Sergej Hloch
Emília Mihalčinová
Josef Foldyna
Jiří Ščučka
Frank Pude
Pavol Hvizdoš
Igor Smolko
Michal Zeleňák
Ján Kľoc
Source :
Tehnički vjesnik, Volume 22, Issue 6
Publication Year :
2015

Abstract

Članak obuhvaća studiju uporabe ultrazvučnog pulzirajućeg mlaza vode odabranih svojstava za razgradnju veze ostvarene pomoću koštanog cementa između cementiranog bedrenog drška i trabekularnog koštanog tkiva, kao potencijalne tehnike za revizijsku artroplastiku. Šest tipova komercijalnog koštanog cementa baziranog na polimetil metakrilatu rabljeni su za ovo istraživanje. Cementi su miješani uz pomoć DePuy - SmartMix® CTS / vakumske zdjele za miješanje. Mehanička svojstva ojačanog koštanog cementa određena su nanoindentacijom. Uzorci koštanog cementa su razgrađeni primjenom tehnologije pulzirajućeg mlaza vode. Tlak vode se mijenjao između 8 i 20 MPa. Kružna mlaznica s promjerom otvora od 0,7 mm je rabljena za rezanje mlazom vode. Odstojanje od ciljanog materijala bilo je 2 mm, a poprečna brzina iznosila je 1 mm/s. Volumen odstranjenog materijala i dubina kreiranih tragova mjereni su pomoću MicroProf FRT optičkog profilometra. Rezultati pozitivno podupiru pretpostavku da pulzirajući mlaz vode ima potencijal biti odgovarajuća tehnika za brzu i sigurnu razgradnju koštanog cementa pri revizijskoj artroplastici.<br />The paper deals with the study of using the selective property of ultrasonic pulsating water jet for the disintegration of the interface created by bone cement between cemented femoral stem and trabecular bone tissue as a potential technique for revision arthroplasty. Six types of commercial bone cements based on Polymethyl Methacrylate were used for investigation. The cements were mixed using the DePuy - SmartMix® CTS / vacuum mixing bowl. Mechanical properties of hardened bone cements were determined by nanoindentation. The bone cement samples were disintegrated using the pulsating water jet technology. The water pressure varied between 8÷20 MPa. A circular nozzle with an orifice diameter of 0,7 mm was used for water jetting. The stand-off distance from the target material was 2 mm and the traverse speed 1 mm/s. The volume of material removal and depth of created traces were measured by MicroProf FRT optical profilometer. The results positively support an assumption that pulsating water jet has a potential to be a suitable technique for the quick and safe disintegration of bone cement during revision arthroplasty.

Details

Language :
English
ISSN :
13303651 and 18486339
Database :
OpenAIRE
Journal :
Tehnički vjesnik, Volume 22, Issue 6
Accession number :
edsair.doi.dedup.....933adbe479f08540778ad21a7e0cf492
Full Text :
https://doi.org/10.17559/tv-20150822145550