- Hexaminolevulinate (HAL) induced Protoporphyrin IX (PpIX) fluorescence is commonly used to differentiate cancer cells from normal cells in vivo, as for instance in blue light cystoscopy for bladder cancer diagnosis. A detailed approach is here provided to use this diagnostic principle ex vivo in an immunosensor device, towards enabling non-invasive cancer diagnostic from body fluids, such as urine. Several factors susceptible to affect the applicability of HAL-assisted diagnosis in body fluids were tested. These included the cell viability and its impact on PpIX fluorescence, the storage condition and shelf life of HAL premix reagent, light exposure (360–450 nm wavelengths) and its corresponding effect on both intensity and bleaching of the PpIX fluorescence as a function of the microscopy imaging conditions. There was no significant decrease in the viability of bladder cancer cells after 6 h at 4 °C (student’s t-test: p > 0.05). The cellular PpIX fluorescence decreased in a time-dependent manner when cancer cells were kept at 4 °C for extended period of time, though this didn’t significantly reduce the fluorescence intensity contrast between cancer and non-cancer cells kept in the same condition for 6 h. HAL premix reagent kept in long term storage at 4 °C induced stronger PpIX fluorescence than reagent kept in the − 20 °C freezer. The PpIX fluorescence was negatively affected by repeated light exposure but increased with illumination intensity and exposure time. Though this applied to both healthy and cancer cell lines, and therefore did not statistically improved the differentiation between cell types. This study revealed important experimental settings that need to be carefully considered to benefit from the analytical potential of HAL induced fluorescence when used in technologies for the diagnosis of cancer from body fluids.
- Subjects :
- Bladder
Science
Microfluidics
030232 urology & nephrology
Protoporphyrins
Biosensing Techniques
Urological cancer
Immunologic Tests
Sensitivity and Specificity
Article
Cancer screening
03 medical and health sciences
chemistry.chemical_compound
0302 clinical medicine
hexaminolevulinate
Cell Line, Tumor
medicine
Humans
biopsy
Viability assay
Liquid biopsy
Cells, Cultured
Cancer
cancer cell
Multidisciplinary
Bladder cancer
Photosensitizing Agents
Protoporphyrin IX
Biological techniques
Liquid Biopsy
Aminolevulinic Acid
medicine.disease
Biosensors
chemistry
Urinary Bladder Neoplasms
030220 oncology & carcinogenesis
Hexaminolevulinate
Cancer cell
Cancer research
Medicine
Urothelium
Ex vivo
Biomarkers
Subjects
Details
- Language :
- English
- ISSN :
- 20452322
- Volume :
- 11
- Issue :
- 1
- Database :
- OpenAIRE
- Journal :
- Scientific Reports
- Accession number :
- edsair.doi.dedup.....931f191200eca8db2f0e3d2cb6b9fad4