Back to Search
Start Over
Utility of trephine reamers in revision hip arthroplasty
- Source :
- The Journal of arthroplasty. 29(1)
- Publication Year :
- 2013
-
Abstract
- Powered trephines used over a femoral component to disrupt the bone component interface can yield acceptable clinical and radiographic outcomes while minimizing direct mechanical injury and indirect thermal necrosis. Thirty-six patients required trephining for fractured stems (16), infection (8), malposition (7), modular junction failure (4), and acetabular exposure (1). Harris Hip Scores (HHS), radiographic healing, and complications were assessed at a follow-up of 50.01 mo. Mean HHS increased from 46.61 preoperatively to 87.78 postoperatively (p
- Subjects :
- Adult
Male
Reoperation
medicine.medical_specialty
Prosthesis-Related Infections
Femoral shaft
Radiography
Arthroplasty, Replacement, Hip
Periprosthetic
Fractures, Bone
medicine
Humans
Orthopedics and Sports Medicine
Femur
Revision hip arthroplasty
Device Removal
Aged
Retrospective Studies
Aged, 80 and over
business.industry
Thermal necrosis
Middle Aged
Surgery
Trephine
Trephining
Female
Hip Prosthesis
Periprosthetic Fractures
business
Subjects
Details
- ISSN :
- 15328406
- Volume :
- 29
- Issue :
- 1
- Database :
- OpenAIRE
- Journal :
- The Journal of arthroplasty
- Accession number :
- edsair.doi.dedup.....925d544928187630a87de64ef6e296ec