Back to Search Start Over

Electrochemical ELISA Based on E. Coli with Autodisplayed Z-Domains

Authors :
Jae Chul Pyun
Min Park
Gu-Yoo
Ju-Kyung Lee
Joachim Jose
Source :
Procedia Engineering. 25:944-947
Publication Year :
2011
Publisher :
Elsevier BV, 2011.

Abstract

Recently, we reported autodisplayed Z-domains on E.coli can highly improve the sensitivity of immunoassays through the orientation control of detection antibodies [1–3]. In this work, the amperometric analysis was applied to the immunoassay based on E.coli cells with autodisplayed Z-domains. For amperometric analaysis, the reduction current of 3,5,3’,5’-tetramethylbenzidine (TMB) was measured at the potential of -50mV and the correlation between the reduction current and the OD value was estimated to be 28 nA/OD and the limit of detection was calculated to be 0.07 in OD unit. In this work, an immunoassay was prepared by immobilizing anti-HRP antibodies to E.coli cells with autodisplayed Z-domains and the amperometric analysis was demonstrated the quantification of bound HRP. For the demonstration of medical diagnosis, C-reactive protein (CRP) was detected by using electrochemical ELISA based on E.coli with autodisplayed Z-domains.

Details

ISSN :
18777058
Volume :
25
Database :
OpenAIRE
Journal :
Procedia Engineering
Accession number :
edsair.doi.dedup.....9232eda58d09b86844a2a3c9eb1af715
Full Text :
https://doi.org/10.1016/j.proeng.2011.12.232