Back to Search
Start Over
Output factor measurement in high dose-per-pulse IORT electron beams
- Publication Year :
- 2019
-
Abstract
- Purpose To assess the capability of different types of detectors to measure relative output factors (OF) at high dose per pulse by comparison with alanine dosimeters, which are independent of dose rate. Methods Measurements were made in 9 MeV and 7 MeV electron beams produced by a Novac7 accelerator for intraoperative radiotherapy. Applicators with diameter of 10-7-6-5 and 4 cm were used. The dose per pulse varied from about 30 mGy, for the 10 cm reference applicator, to about 70 mGy, for the 4 cm applicator. Five types of plane-parallel ionization chambers (PTW Advanced Markus, Markus and Roos, IBA PPC40 and PPC05), two types of silicon diodes (PTW 60017 and IBA EFD3G) and a PTW 60019 microDiamond were considered. For the ionization chambers, correction factors for ion recombination effects were determined for each applicator using a modified two-voltage-analysis method that includes the free-electron component. Results Reference OF values were determined by alanine dosimeters with a standard combined uncertainty of 0.8%. Deviations from the reference OFs were generally within 1.5% for all the detectors, hence within the 95% confidence interval of alanine measurements. Larger deviations of up to about 2% obtained in a few cases are consistent with a 0.7% long-term reproducibility of OF measurements. Conclusions Comparison with alanine measurements demonstrated that all the detectors considered in this work can be used to measure OFs in high dose-per-pulse electron beams with an accuracy better than 2%, provided that appropriate corrections for ion recombination effects are applied when using ionization chambers.
- Subjects :
- Materials science
Ion recombination
IORT
Biophysics
General Physics and Astronomy
Reproducibility of Result
Electrons
Electron
Radiation Dosage
Dose per pulse
Output factors
Saturation correction
Particle Accelerators
Radiometry
Radiotherapy Dosage
Reproducibility of Results
Output factor
030218 nuclear medicine & medical imaging
Ion
law.invention
03 medical and health sciences
0302 clinical medicine
Optics
law
Ionization
Radiology, Nuclear Medicine and imaging
Particle Accelerator
Diode
Reproducibility
Dosimeter
business.industry
Detector
Particle accelerator
General Medicine
030220 oncology & carcinogenesis
business
Subjects
Details
- Language :
- English
- Database :
- OpenAIRE
- Accession number :
- edsair.doi.dedup.....91cb2616de21e5d167deefc386a31ade