Back to Search
Start Over
Potential reference measurement procedures for PBDE in surface water at levels required by the EU Water Frame Directive
- Source :
- Swart, C.; Gantois, F.; Petrov, P.; Entwisle, J.; Goenaga_Infante, H.; Nousiainen, M.; Bilsel, M.; Binici, B.; Gonzalez-Gago, A.; Proefrock, D.; Goeren, A.C.: Potential reference measurement procedures for PBDE in surface water at levels required by the EU Water Frame Directive. In: Talanta. Vol. 152 (2016) 251-258. (DOI: 10.1016/j.talanta.2016.01.066)
- Publication Year :
- 2016
-
Abstract
- Polybrominated diphenylethers (PBDE), used as flame retardants, are named as priority substances in the Directive 2000/60/EC of the European parliament and of the council establishing a framework for Community action in the field of water policy. An annual average environmental quality standard (EQS) for inland surface waters of 0.0005 mu g/L (0.0002 mu g/L for other surface waters) for PBDE congeners involved in the technical penta-PBDE mixtures containing PBDE with five bromine atoms has been established. The directives focus especially on the congeners PBDE 28, 47, 99, 100, 153 and 154 contained in the penta-PBDE mixture. Up to now, no reference measurement procedures have been established reaching the limits of quantification (LOQs) and the associated uncertainties as defined in the directives with results traceable to the SI. Within a recent European project on metrology, different approaches for the traceable quantification of PBDE, based on liquid/liquid or solid phase extraction followed by the detection with gas chromatography coupled to either inductively coupled plasma mass spectrometry or triple quadrupole mass spectrometry, were investigated and the related LOQs and expanded uncertainties of the results were compared. A complete uncertainty budget for each method was estimated according to the Guide to the Expression of Uncertainty in Measurement (GUM). All presented analytical procedures can serve as reference measurement procedures regarding the LOQs and their associated expanded uncertainties for monitoring the six priority PBDEs named above. LOQs as low as 0.026 ng/kg with an associated expanded uncertainty of 0.002 ng/kg could be achieved (C) 2016 The Authors. Published by Elsevier B.V.
- Subjects :
- Chemistry(all)
Method validation
Liquid-Liquid Extraction
Fresh Water
010501 environmental sciences
PBDE
01 natural sciences
Analytical Chemistry
Limit of Detection
Environmental monitoring
Water Frame Directive
Halogenated Diphenyl Ethers
Humans
Solid phase extraction
Inductively coupled plasma mass spectrometry
0105 earth and related environmental sciences
Flame Retardants
Chemistry
Spectrophotometry, Atomic
010401 analytical chemistry
Solid Phase Extraction
Water
Directive
6. Clean water
0104 chemical sciences
13. Climate action
Environmental chemistry
Measurement uncertainty
Analytical procedures
Gas chromatography
Surface water
IDMS
Water Pollutants, Chemical
Environmental Monitoring
Subjects
Details
- ISSN :
- 00399140
- Database :
- OpenAIRE
- Journal :
- Swart, C.; Gantois, F.; Petrov, P.; Entwisle, J.; Goenaga_Infante, H.; Nousiainen, M.; Bilsel, M.; Binici, B.; Gonzalez-Gago, A.; Proefrock, D.; Goeren, A.C.: Potential reference measurement procedures for PBDE in surface water at levels required by the EU Water Frame Directive. In: Talanta. Vol. 152 (2016) 251-258. (DOI: 10.1016/j.talanta.2016.01.066)
- Accession number :
- edsair.doi.dedup.....91a659dc977608b6dffdbb2a5998a286
- Full Text :
- https://doi.org/10.1016/j.talanta.2016.01.066)