Back to Search
Start Over
Cálculo de lente intraocular en casos complicados: el método «Silguero»
- Source :
- Archivos de la Sociedad Española de Oftalmología, Volume: 80, Issue: 10, Pages: 589-595, Published: OCT 2005, Archivos de la Sociedad Española de Oftalmología v.80 n.10 2005, SciELO España. Revistas Científicas Españolas de Ciencias de la Salud, instname
- Publication Year :
- 2005
- Publisher :
- Sociedad Española de Oftalmología, 2005.
-
Abstract
- espanolObjetivo: Mostrar un nuevo metodo para el calculo de la lente intraocular (LIO) en pacientes intervenidos de cirugia refractiva corneal en los que la aplicacion de otros metodos no es posible por la falta de datos. Tambien es aplicable en otras situaciones de alta dificultad en el calculo de la LIO y en casos de intercambio de LIO por sorpresa refractiva. Metodos: Se realiza la facoemulsificacion y antes de implantar la LIO se refracciona al paciente, utilizando el dato de la refraccion en afaquia como unica variable para la aplicacion de nuestra formula, que se basa en la correspondencia existente entre la graduacion en gafas (12 mm) y la potencia de la LIO a nivel de plano cristaliniano. Se ha aplicado en tres pacientes en los que ningun metodo de calculo era aplicable. Resultados: Los tres pacientes han quedado con un equivalente esferico inferior a 1 dioptria. Conclusiones: Creemos que esta formula es valida para algunas situaciones en que otras formulas no pueden ser aplicadas por falta de variables. EnglishPurpose: To report a new method for intraocular lens (IOL) calculation in patients treated by corneal refractive surgery, in whom the application of other methods is not possible because of the absence of necessary data. This method is also applicable in other situations where the IOL calculation is difficult and in cases of IOL exchange because of unexpected refractive difficulties. Methods: We performed phaco-emulsifications, refracting the patients eye before IOL implantation, using the refraction data in aphakia as the only variable for the application of the formula, which itself is based on the existing correlation between the graduation of glasses (12 mm) and the IOL power at the lens level. The formula has been applied in 3 patients in whom no other calculation method was applicable. Results: After the appropriate intervention, the 3 patients presented a spherical equivalent below 1 diopter. Conclusion: We believe this formula is valid in some situations where other formulas cannot be applied because of the absence of the necessary variables.
Details
- Language :
- Spanish; Castilian
- Database :
- OpenAIRE
- Journal :
- Archivos de la Sociedad Española de Oftalmología, Volume: 80, Issue: 10, Pages: 589-595, Published: OCT 2005, Archivos de la Sociedad Española de Oftalmología v.80 n.10 2005, SciELO España. Revistas Científicas Españolas de Ciencias de la Salud, instname
- Accession number :
- edsair.doi.dedup.....90da44cf3c4e26fdc7695f03bae22874