Minimally invasive plate osteosynthesis for midshaft clavicular fractures using superior anatomic plating
- Source :
- Journal of Shoulder and Elbow Surgery. 25:e7-e12
- Publication Year :
- 2016
- Publisher :
- Elsevier BV, 2016.
-
Abstract
- Background The minimally invasive plate osteosynthesis procedure has been widely applied for long-bone fixations; however, this technique is not commonly used for clavicular midshaft fractures. In this study, we introduced this technique for midshaft clavicular fractures using superior anatomic locking plates and evaluated its clinical and radiographic outcomes. Materials and methods From June 2013 to July 2014, 15 patients with acute midshaft clavicular fractures were treated with the minimally invasive plate osteosynthesis technique using a 3.5-mm clavicular superior anatomic locking plate. Anteroposterior plain X-ray images of the clavicle were taken at 4-week intervals until union was observed. The last clinical follow-up assessments were performed postoperatively at a mean of 16.54 months (range, 10-23 months). In addition, for clinical evaluations, the Constant score and the Disability of the Arm, Shoulder and Hand score were assessed. Results The average operative time was 60.2 ± 20.1 minutes (range, 40-80 minutes), with blood loss of 25 ± 5 mL (range, 20-30 mL) during the operation. The mean union time for the patients was 10.1 ± 1.4 weeks (range, 8-12 weeks), and no delayed union or nonunion was observed. There were no major complications, including infections, plate breakages, or neurovascular injuries. No skin irritation was observed, and only 2 patients felt local incision numbness. All patients obtained satisfactory shoulder functions. The mean Constant score was 99 ± 1.8 (range, 95-100), and the mean Disability of the Arm, Shoulder and Hand score was 3.8 ± 2.9 (range, 0-10) at the last control visit. Conclusion The minimally invasive plate osteosynthesis procedure that was introduced in this study for midshaft clavicular fractures with superior anatomic locking plate is a reproducible procedure and an alternative to conventional operative methods.
- Subjects :
- Adult
Male
medicine.medical_specialty
Time Factors
Radiography
Operative Time
Nonunion
Blood Loss, Surgical
Bone healing
Fracture Fixation, Internal
Fractures, Bone
03 medical and health sciences
0302 clinical medicine
Clavicular fractures
Bone plate
medicine
Humans
Minimally Invasive Surgical Procedures
Orthopedics and Sports Medicine
030212 general & internal medicine
Fracture Healing
030222 orthopedics
Shoulder Joint
business.industry
General Medicine
Middle Aged
Neurovascular bundle
medicine.disease
Clavicle
Surgery
medicine.anatomical_structure
Female
Shoulder joint
business
Bone Plates
Subjects
Details
- ISSN :
- 10582746
- Volume :
- 25
- Database :
- OpenAIRE
- Journal :
- Journal of Shoulder and Elbow Surgery
- Accession number :
- edsair.doi.dedup.....9024cd23a91946f01c7e0b41d589e5f2
- Full Text :
- https://doi.org/10.1016/j.jse.2015.06.024