Back to Search Start Over

Robust Optical Flow Estimation in Cardiac Ultrasound Images Using a Sparse Representation

Authors :
Olivier Lairez
Jean-Yves Tourneret
Adrian Basarab
Nora Ouzir
CoMputational imagINg anD viSion (IRIT-MINDS)
Institut de recherche en informatique de Toulouse (IRIT)
Université Toulouse 1 Capitole (UT1)
Université Fédérale Toulouse Midi-Pyrénées-Université Fédérale Toulouse Midi-Pyrénées-Université Toulouse - Jean Jaurès (UT2J)-Université Toulouse III - Paul Sabatier (UT3)
Université Fédérale Toulouse Midi-Pyrénées-Centre National de la Recherche Scientifique (CNRS)-Institut National Polytechnique (Toulouse) (Toulouse INP)
Université Fédérale Toulouse Midi-Pyrénées-Université Toulouse 1 Capitole (UT1)
Université Fédérale Toulouse Midi-Pyrénées
Université Toulouse III - Paul Sabatier (UT3)
Institut des Maladies Métaboliques et Cardiovasculaires (I2MC)
Institut National de la Santé et de la Recherche Médicale (INSERM)-Université Toulouse III - Paul Sabatier (UT3)
Université Fédérale Toulouse Midi-Pyrénées-Université Fédérale Toulouse Midi-Pyrénées
Institut National Polytechnique (Toulouse) (Toulouse INP)
Centre National de la Recherche Scientifique - CNRS (FRANCE)
Institut National Polytechnique de Toulouse - Toulouse INP (FRANCE)
Institut National de la Santé et de la Recherche Médicale - INSERM (FRANCE)
Université Toulouse III - Paul Sabatier - UT3 (FRANCE)
Université Toulouse - Jean Jaurès - UT2J (FRANCE)
Université Toulouse 1 Capitole - UT1 (FRANCE)
Centre Hospitalier Universitaire de Toulouse - CHU Toulouse (FRANCE)
Source :
IEEE Transactions on Medical Imaging, IEEE Transactions on Medical Imaging, Institute of Electrical and Electronics Engineers, 2019, 38 (3), pp.741-752. ⟨10.1109/TMI.2018.2870947⟩
Publication Year :
2019
Publisher :
HAL CCSD, 2019.

Abstract

International audience; This paper introduces a robust 2-D cardiac motion estimation method. The problem is formulated as an energy minimization with an optical flow-based data fidelity term and two regularization terms imposing spa- tial smoothness and the sparsity of the motion field in an appropriate cardiac motion dictionary. Robustness to outliers, such as imaging artefacts and anatomical motion boundaries, is introduced using robust weighting functions for the data fidelity term as well as for the spatial and sparse regularizations. The motion fields and the weights are com- puted jointly using an iteratively re-weighted minimization strategy. The proposed robust approach is evaluated on syn- thetic data and realistic simulation sequences with available ground-truth by comparing the performance with state-of- the-art algorithms. Finally, the proposed method is validated using two sequences of in vivo images. The obtained results show the interest of the proposed approach for 2-D cardiac ultrasound imaging.

Details

Language :
English
ISSN :
02780062
Database :
OpenAIRE
Journal :
IEEE Transactions on Medical Imaging, IEEE Transactions on Medical Imaging, Institute of Electrical and Electronics Engineers, 2019, 38 (3), pp.741-752. ⟨10.1109/TMI.2018.2870947⟩
Accession number :
edsair.doi.dedup.....8fa2807010b9d3bf6d131f804dc048ec