- Koivunoro, H, Kumada, H, Seppälä, T, Kotiluoto, P, Auterinen, I, Kankaanranta, L & Savolainen, S 2009, ' Comparative study of dose calculations with SERA and JCDS treatment planning systems ', Applied Radiation and Isotopes, vol. 67, no. 7-8 Supplement, pp. S126-S129 . https://doi.org/10.1016/j.apradiso.2009.03.092
- Publication Year :
- 2009
-
Abstract
- Three treatment planning systems developed for clinical boron neutron capture therapy (BNCT) use are SERA developed by INL/Montana State University, NCTPlan developed by the Harvard-MIT and the CNEA group and JAEA computational dosimetry system (JCDS) developed by Japan Atomic Energy Agency (JAEA) in Japan. Previously, performance of the SERA and NCTPlan has been compared in various studies. In this preliminary study, the dose calculations performed with SERA and JCDS systems were compared in single brain cancer patient case with the FiR 1 epithermal neutron beam. A two-field brain cancer treatment plan was performed with the both codes. The dose components to normal brain, tumor and planning target volume (PTV) were calculated and compared in case of one radiation field and combined two fields. The depth dose distributions and the maximum doses in regions of interest were compared. Calculations with the treatment planning systems for the thermal neutron induced ((10)B and nitrogen) dose components and photon dose were in good agreement. Higher discrepancy in the fast neutron dose calculations was found. In case of combined two-field treatment plan, overall discrepancy of the maximum weighted dose was approximately 3% for normal brain and PTV and approximately 4% for tumor dose.
- Subjects :
- Radiation-Sensitizing Agents
Materials science
Dose calculation
Nitrogen
Planning target volume
Boron Neutron Capture Therapy
030218 nuclear medicine & medical imaging
Fast Neutrons
03 medical and health sciences
0302 clinical medicine
Isotopes
Japan
SDG 3 - Good Health and Well-being
MCNP
Dosimetry
Humans
Radiation treatment planning
Boron
Neutron dose
Photons
Radiation
business.industry
Brain Neoplasms
Radiotherapy Planning, Computer-Assisted
JCDS
Epithermal neutron
Neutron temperature
United States
3. Good health
Neutron capture
SERA
Boron neutron capture therapy (BNCT)
030220 oncology & carcinogenesis
Nuclear medicine
business
Treatment planning
Software
Subjects
Details
- Language :
- English
- Database :
- OpenAIRE
- Journal :
- Koivunoro, H, Kumada, H, Seppälä, T, Kotiluoto, P, Auterinen, I, Kankaanranta, L & Savolainen, S 2009, ' Comparative study of dose calculations with SERA and JCDS treatment planning systems ', Applied Radiation and Isotopes, vol. 67, no. 7-8 Supplement, pp. S126-S129 . https://doi.org/10.1016/j.apradiso.2009.03.092
- Accession number :
- edsair.doi.dedup.....8c31685d86956ffcd7fe4e1908e1a7c0