Predictors of Cardiac Implantable Electronic Device Artifact on Cardiac MRI: The Utility of a Device Related Score
- Source :
- Heart, Lung and Circulation. 30:1348-1355
- Publication Year :
- 2021
- Publisher :
- Elsevier BV, 2021.
-
Abstract
- Cardiac magnetic resonance imaging (CMR) image quality can be degraded by artifact in patients with cardiac implantable electronic devices (CIED). We aimed to establish a clinical risk score, so patient selection for diagnostic CMR could be optimised.In this retrospective cohort study, CMRs performed for clinical use in subjects with CIED from January 2016 to May 2019 were reviewed. Subject anthropometry, CIED generator/lead specifications and pre-scan chest X-ray (CXR) measurements were collected. Generator-related artifact size was measured on axial steady state free precession images. Interpretability of late gadolinium enhancement (LGE) imaging was performed based on a three-grade visual score attributed to each of 17 myocardial segments.Fifty-seven (57) patients (59±16 years, 74% male) fitted the inclusion criteria. Artifact precluded left ventricle (LV) evaluation (≥5 segments) in 17 (30%). Artifact was more common with implantable cardioverter-defibrillators, related to generator volume, mass, height, width, thickness, and area, along with right ventricular (RV) lead length and diameter (all p0.05). Artifact was associated with distance from generator to LV apex, generator to RV lead tip and shortest distance from generator to heart on CXR (all p0.05). On multivariable regression modelling, RV lead diameter (OR 5.861, 95% CI 1.866-18.407, p=0.002) and distance from generator to LV apex (OR 0.693, 95% CI 0.511-0.940, p=0.019) were independent predictors of artifact. Multivariable predictors were used to develop Device Related CMR Artifact Prediction Score (DR-CAPS), where all patients with DR-CAPS=0 had fully interpretable LGE imaging.Simple, readily available measures, such as lead characteristics and pre-scan CXR measures, can stratify patients via an artifact prediction score to optimise selection for diagnostic CMR.
- Subjects :
- Male
Pulmonary and Respiratory Medicine
medicine.medical_specialty
Image quality
medicine.medical_treatment
Contrast Media
Gadolinium
030204 cardiovascular system & hematology
03 medical and health sciences
0302 clinical medicine
Cardiac magnetic resonance imaging
medicine
Humans
In patient
030212 general & internal medicine
Lead (electronics)
Retrospective Studies
Artifact (error)
medicine.diagnostic_test
business.industry
Retrospective cohort study
Implantable cardioverter-defibrillator
Magnetic Resonance Imaging
Defibrillators, Implantable
medicine.anatomical_structure
Ventricle
Female
Radiology
Electronics
Artifacts
Cardiology and Cardiovascular Medicine
business
Subjects
Details
- ISSN :
- 14439506
- Volume :
- 30
- Database :
- OpenAIRE
- Journal :
- Heart, Lung and Circulation
- Accession number :
- edsair.doi.dedup.....8b47301cdd748b4779fe154e50f79ad3
- Full Text :
- https://doi.org/10.1016/j.hlc.2021.02.011