Back to Search Start Over

Cinética da floculação: um estudo comparativo no uso do cloreto de polialumínio com alta e baixa basicidade e o sulfato de alumínio

Authors :
Geane Fagundes Garcia
Adriano Gonçalves dos Reis
Roberta Mitani Seneda
Source :
Engenharia Sanitaria e Ambiental, Vol 26, Iss 2, Pp 283-290 (2021), Engenharia Sanitaria e Ambiental, Volume: 26, Issue: 2, Pages: 283-290, Published: 09 APR 2021, Engenharia Sanitaria e Ambiental v.26 n.2 2021, Engenharia Sanitaria e Ambiental, Associação Brasileira de Engenharia Sanitária e Ambiental (ABES), instacron:ABES
Publication Year :
2021
Publisher :
Brazilian Association of Sanitary and Environmental Engineering, 2021.

Abstract

RESUMO O sulfato de alumínio (SA) é amplamente utilizado como coagulante no tratamento de água de abastecimento via ciclo completo. Coagulantes alternativos estão disponíveis no mercado, dentre eles o cloreto de polialumínio (PAC). Porém, estudos comparativos entre o SA e os PACs de alta (PAC-AB) e baixa (PAC-BB) basicidade em relação à cinética de floculação ainda são escassos. Nesse sentido, o intuito deste trabalho foi comparar o uso de PAC-BB, PAC-AB e SA via coagulação, floculação e sedimentação, bem como avaliar o efeito na condutividade elétrica, na formação de lodo, na alcalinidade, no pH e na remoção de turbidez baseado na cinética de floculação e morfologia do floco formado. Os resultados indicaram aumento de 8,1% na condutividade elétrica e de 30,6 mg.L-1 na formação de lodo; não houve diferença significativa entre os coagulantes. O PAC-AB apresentou menor consumo de alcalinidade e, consequentemente, menor redução no pH. A remoção de turbidez foi estatisticamente igual entre o PAC-BB (91,8 ± 3,7%) e o PAC-AB (91,5 ± 1,1%), porém maior que no SA (82,2 ± 6,4%). Essa diferença se acentua com o aumento da velocidade crítica de sedimentação. A constante de agregação dos flocos (K A ) apresenta resultados estatisticamente iguais entre os coagulantes, e o melhor desempenho de remoção de turbidez dos PACs em relação ao SA se deve à menor constante de ruptura do floco (K B ), podendo-se inferir, portanto, que os flocos formados com o PAC-AB e o PAC-BB são mais fortes que os formados com o SA. ABSTRACT Aluminum sulfate (AS) is widely used as a coagulant in conventional drinking water treatment facilities. Alternative coagulants are commercially available, including polyaluminium chloride (PAC). However, comparative studies between AS and PAC with high (PAC-AB) and low (PAC-BB) basicity regarding flocculation kinetics are still scarce. In this sense, the aim of this work is to compare the use of PAC-BB, PAC-AB, and AS via coagulation, flocculation, and sedimentation as well as to evaluate the effect on electrical conductivity, sludge formation, alkalinity, pH, and turbidity removal based on flocculation kinetic and floc morphology. The results indicated that the increase in electrical conductivity was 8.1% and the sludge formation was 30.6 mg.L-1, and that there was no significant difference between coagulants. PAC-AB presented the lowest alkalinity consumption and, consequently, the lowest pH reduction. Turbidity removal was statistically equal between PAC-BB (91.8 ± 3.7%) and PAC-AB (91.5 ± 1.1%), but higher than in AS (82.2 ± 6.4%). This difference is accentuated with the increase in critical settling velocity. The floc aggregation constant (K A ) is statistically equal among the coagulants, and the better turbidity removal performance of the PACs in relation to the AS is due to the lower floc breaking constant (K B ) and may, therefore, infer that the flocs formed with PAC-AB and PAC-BB are stronger than those formed with SA.

Details

Language :
English
ISSN :
18094457
Volume :
26
Issue :
2
Database :
OpenAIRE
Journal :
Engenharia Sanitaria e Ambiental
Accession number :
edsair.doi.dedup.....8a947716acc205cba22782e69cc9024d