Back to Search Start Over

Performance of the Hypotension Prediction Index with non-invasive arterial pressure waveforms in non-cardiac surgical patients

Authors :
Barak Cohen
Jos J. Settels
Sai Buddi
Zhongping Jian
Daniel I. Sessler
Tetsuya Shimada
Feras Hatib
Kamal Maheshwari
Source :
Journal of Clinical Monitoring and Computing
Publication Year :
2020
Publisher :
Springer Science and Business Media LLC, 2020.

Abstract

An algorithm derived from machine learning uses the arterial waveform to predict intraoperative hypotension some minutes before episodes, possibly giving clinician’s time to intervene and prevent hypotension. Whether the Hypotension Prediction Index works well with noninvasive arterial pressure waveforms remains unknown. We therefore evaluated sensitivity, specificity, and positive predictive value of the Index based on non-invasive arterial waveform estimates. We used continuous hemodynamic data measured from ClearSight (formerly Nexfin) noninvasive finger blood pressure monitors in surgical patients. We re-evaluated data from a trial that included 320 adults ≥ 45 years old designated ASA physical status 3 or 4 who had moderate-to-high-risk non-cardiac surgery with general anesthesia. We calculated sensitivity and specificity for predicting hypotension, defined as mean arterial pressure ≤ 65 mmHg for at least 1 min, and characterized the relationship with receiver operating characteristics curves. We also evaluated the number of hypotensive events at various ranges of the Hypotension Prediction Index. And finally, we calculated the positive predictive value for hypotension episodes when the Prediction Index threshold was 85. The algorithm predicted hypotension 5 min in advance, with a sensitivity of 0.86 [95% confidence interval 0.82, 0.89] and specificity 0.86 [0.82, 0.89]. At 10 min, the sensitivity was 0.83 [0.79, 0.86] and the specificity was 0.83 [0.79, 0.86]. And at 15 min, the sensitivity was 0.75 [0.71, 0.80] and the specificity was 0.75 [0.71, 0.80]. The positive predictive value of the algorithm prediction at an Index threshold of 85 was 0.83 [0.79, 0.87]. A Hypotension Prediction Index of 80–89 provided a median of 6.0 [95% confidence interval 5.3, 6.7] minutes warning before mean arterial pressure decreased to

Details

ISSN :
15732614 and 13871307
Volume :
35
Database :
OpenAIRE
Journal :
Journal of Clinical Monitoring and Computing
Accession number :
edsair.doi.dedup.....8a066eaf3d866b8f551779324b101724
Full Text :
https://doi.org/10.1007/s10877-020-00463-5