Back to Search
Start Over
Technical challenges of quantitative chest MRI data analysis in a large cohort pediatric study
- Source :
- Nguyen, A H, Perez-Rovira, A, Wielopolski, P A, Hernandez Tamames, J A, Duijts, L, de Bruijne, M, Aliverti, A, Pennati, F, Ivanovska, T, Tiddens, H A W M & Ciet, P 2019, ' Technical challenges of quantitative chest MRI data analysis in a large cohort pediatric study ', European Radiology, vol. 29, no. 6, pp. 2770–2782 . https://doi.org/10.1007/s00330-018-5863-7, European Radiology, European Radiology, 29(6), 2770-2782. Springer-Verlag
- Publication Year :
- 2018
- Publisher :
- Springer Science and Business Media LLC, 2018.
-
Abstract
- Objectives This study was conducted in order to evaluate the effect of geometric distortion (GD) on MRI lung volume quantification and evaluate available manual, semi-automated, and fully automated methods for lung segmentation. Methods A phantom was scanned with MRI and CT. GD was quantified as the difference in phantom’s volume between MRI and CT, with CT as gold standard. Dice scores were used to measure overlap in shapes. Furthermore, 11 subjects from a prospective population-based cohort study each underwent four chest MRI acquisitions. The resulting 44 MRI scans with 2D and 3D Gradwarp were used to test five segmentation methods. Intraclass correlation coefficient, Bland–Altman plots, Wilcoxon, Mann–Whitney U, and paired t tests were used for statistics. Results Using phantoms, volume differences between CT and MRI varied according to MRI positions and 2D and 3D Gradwarp correction. With the phantom located at the isocenter, MRI overestimated the volume relative to CT by 5.56 ± 1.16 to 6.99 ± 0.22% with body and torso coils, respectively. Higher Dice scores and smaller intraobject differences were found for 3D Gradwarp MR images. In subjects, semi-automated and fully automated segmentation tools showed high agreement with manual segmentations (ICC = 0.971–0.993 for end-inspiratory scans; ICC = 0.992–0.995 for end-expiratory scans). Manual segmentation time per scan was approximately 3–4 h and 2–3 min for fully automated methods. Conclusions Volume overestimation of MRI due to GD can be quantified. Semi-automated and fully automated segmentation methods allow accurate, reproducible, and fast lung volume quantification. Chest MRI can be a valid radiation-free imaging modality for lung segmentation and volume quantification in large cohort studies. Key Points • Geometric distortion varies according to MRI setting and patient positioning. • Automated segmentation methods allow fast and accurate lung volume quantification. • MRI is a valid radiation-free alternative to CT for quantitative data analysis. Electronic supplementary material The online version of this article (10.1007/s00330-018-5863-7) contains supplementary material, which is available to authorized users.
- Subjects :
- Male
medicine.medical_specialty
Population
Phantoms
Imaging phantom
Imaging
030218 nuclear medicine & medical imaging
Cohort Studies
03 medical and health sciences
Imaging, Three-Dimensional
Magnetic resonance imaging
0302 clinical medicine
Lung
Lung volume measurements
medicine
Humans
Radiology, Nuclear Medicine and imaging
Segmentation
Lung volumes
Magnetic Resonance
Prospective Studies
Child
education
Neuroradiology
education.field_of_study
medicine.diagnostic_test
Phantoms, Imaging
business.industry
Reproducibility of Results
Isocenter
General Medicine
Gold standard (test)
Magnetic Resonance Imaging
Female
Lung Volume Measurements
ROC Curve
030220 oncology & carcinogenesis
Three-Dimensional
Radiology
business
Subjects
Details
- ISSN :
- 14321084 and 09387994
- Volume :
- 29
- Database :
- OpenAIRE
- Journal :
- European Radiology
- Accession number :
- edsair.doi.dedup.....89eb3444badfb60eecbf9b609009b72c