Back to Search Start Over

Camera calibration strategy of the SST-1M prototype of the Cherenokov Telescope Array

Authors :
Prandini, E.
Heller, M.
Lyard, E.
Schioppa, E.
Neronov, A.
Bilnik, W.
Błocki, J.
Bogacz, L.
Bulik, T.
Cadoux, F.
Christov, A.
Curyło, M.
Della Volpe, D.
Dyrda, M.
Favre, Y.
Frankowski, A.
Grudniki, L.
Grudzińska, M.
Idźkowski, B.
Jamrozy, M.
Janiak, M.
Kasperek, J.
Lalik, K.
Mach, E.
Mandat, D.
Marszałekc, A.
Michałowski, J.
Moderski, R.
Montaruli, T.
Niemiec, J.
Ostrowski, M.
Pásko, P.
Miroslav Pech
Porcelli, A.
Rajda, P.
Rameez, M.
Schovanek, P.
Seweryn, K.
Skowron, K.
Sliusar, V.
Sowiński, M.
Stawarz, L.
Stodulska, M.
Stodulski, M.
Toscano, S.
Troyano Pujadas, I.
Walter, R.
Wiȩcek, M.
Zagdanński, A.
Ziȩtara, K.
Zychowski, P.
Prandini, E.
Heller, M.
Lyard, E.
Schioppa, E.
Neronov, A.
Bilnik, W.
Błocki, J.
Bogacz, L.
Bulik, T.
Cadoux, F.
Christov, A.
Curyło, M.
della Volpe, D.
Dyrda, M.
Favre, Y.
Frankowski, A.
Grudnik, Ł.
Grudzińska, M.
Idźkowski, B.
Jamrozy, M.
Janiak, M.
Kasperek, J.
Lalik, K.
Mach, E.
Mandat, D.
Marszałek, A.
Michałowski, J.
Moderski, R.
Montaruli, T.
Niemiec, J.
Ostrowski, M.
Paśko, P.
Pech, M.
Porcelli, A.
Rameez, M.
Rajda, P.
Schovanek, P.
Seweryn, K.
Skowron, K.
Sliusar, V.
Sowiński, M.
Stawarz, Ł.
Stodulska, M.
Stodulski, M.
Toscano, S.
Troyano Pujadas, I.
Walter, R.
Więcek, M.
Zagdański, A.
Ziętara, K.
Żychowski, P.
Source :
Scopus-Elsevier, Università del Salento-IRIS

Abstract

The SST-1M telescope is one of the prototypes under construction proposed to be part of the future Cherenkov Telescope Array. It uses a standard Davis-Cotton design for the optics and telescope structure, with a dish diameter of 4 meters and a large field-of-view of 9 degrees. The innovative camera design is composed of a photo-detection plane with 1296 pixels including entrance window, light concentrators, Silicon Photomultipliers (SiPMs), and pre-amplifier stages together with a fully digital readout and trigger electronics, DigiCam. In this contribution we give a general description of the analysis chain designed for the SST-1M prototype. In particular we focus on the calibration strategy used to convert the SiPM signals registered by DigiCam to the quantities needed for Cherenkov image analysis. The calibration is based on an online feedback system to stabilize the gain of the SiPMs, as well as dedicated events (dark count, pedestal, and light flasher events) to be taken during the normal operation of the prototype.<br />In Proceedings of the 34th International Cosmic Ray Conference (ICRC2015), The Hague, The Netherlands. All CTA contributions at arXiv:1508.05894

Details

Database :
OpenAIRE
Journal :
Scopus-Elsevier, Università del Salento-IRIS
Accession number :
edsair.doi.dedup.....8964c73ae9bcb0f966eef73c49e66646