Back to Search
Start Over
Comparison of Atmospheric Pressure Chemical Ionization, Electrospray Ionization, and Atmospheric Pressure Photoionization for the Determination of Cyclosporin A in Rat Plasma
- Source :
- Analytical Chemistry. 77:541-548
- Publication Year :
- 2004
- Publisher :
- American Chemical Society (ACS), 2004.
-
Abstract
- Atmospheric pressure chemical ionization was compared with electrospray ionization and atmospheric pressure photoionization (APPI) as an interface of high-performance liquid chromatography (HPLC)-tandem mass spectrometry (MS/MS) for the determination of cyclosporin A (CsA) in biological fluids in support of in vivo pharmacodynamic studies. These ion sources were investigated in terms of their suitability and sensitivity for the detection of CsA. The effects of the eluent flow rate and composition as well as the nebulizer temperatures on the photoionization efficiency of CsA in the positive ion mode under normal-phase HPLC conditions were explored. The ionization mechanism in the APPI environment with and without the use of the dopant was studied using two test compounds and a few solvent systems employed for normal-phase chromatography. The test compounds were observed to be ionized mainly by proton transfer with the self-protonated solvent molecules produced through photon irradiation. Furthermore, ion suppression due to sample matrix interference in the normal-phase HPLC-APPI-MS/MS system was monitored by the postcolumn infusion technique. The applicability of these proposed HPLC-API-MS/MS approaches for the determination of CsA at low nanogram per milliliter levels in rat plasma was examined. These proposed methods were then compared with respect to specificity, linearity, detection limit, and accuracy.
- Subjects :
- Air Ionization
Spectrometry, Mass, Electrospray Ionization
Chemical ionization
Chromatography
Photochemistry
Chemistry
Electrospray ionization
Analytical chemistry
Reproducibility of Results
Atmospheric-pressure chemical ionization
Photoionization
Mass spectrometry
Sensitivity and Specificity
Ion source
Rats
Analytical Chemistry
Atmospheric-pressure laser ionization
Atmospheric Pressure
Tandem Mass Spectrometry
Cyclosporine
Physics::Atomic and Molecular Clusters
Animals
Direct electron ionization liquid chromatography–mass spectrometry interface
Chromatography, High Pressure Liquid
Subjects
Details
- ISSN :
- 15206882 and 00032700
- Volume :
- 77
- Database :
- OpenAIRE
- Journal :
- Analytical Chemistry
- Accession number :
- edsair.doi.dedup.....88f3f93fde70aa89cf4508eab26503cb
- Full Text :
- https://doi.org/10.1021/ac040144m