Back to Search
Start Over
Development of quantitative screen for 1550 chemicals with GC-MS
- Source :
- Analytical and Bioanalytical Chemistry
- Publication Year :
- 2018
- Publisher :
- Springer Berlin Heidelberg, 2018.
-
Abstract
- With hundreds of thousands of chemicals in the environment, effective monitoring requires high-throughput analytical techniques. This paper presents a quantitative screening method for 1550 chemicals based on statistical modeling of responses with identification and integration performed using deconvolution reporting software. The method was evaluated with representative environmental samples. We tested biological extracts, low-density polyethylene, and silicone passive sampling devices spiked with known concentrations of 196 representative chemicals. A multiple linear regression (R2 = 0.80) was developed with molecular weight, logP, polar surface area, and fractional ion abundance to predict chemical responses within a factor of 2.5. Linearity beyond the calibration had R2 > 0.97 for three orders of magnitude. Median limits of quantitation were estimated to be 201 pg/μL (1.9× standard deviation). The number of detected chemicals and the accuracy of quantitation were similar for environmental samples and standard solutions. To our knowledge, this is the most precise method for the largest number of semi-volatile organic chemicals lacking authentic standards. Accessible instrumentation and software make this method cost effective in quantifying a large, customizable list of chemicals. When paired with silicone wristband passive samplers, this quantitative screen will be very useful for epidemiology where binning of concentrations is common. Graphical abstractA multiple linear regression of chemical responses measured with GC-MS allowed quantitation of 1550 chemicals in samples such as silicone wristbands. Electronic supplementary material The online version of this article (10.1007/s00216-018-0997-7) contains supplementary material, which is available to authorized users.
- Subjects :
- 010501 environmental sciences
Standard solution
01 natural sciences
Biochemistry
Analytical Chemistry
Passive sampling devices
Chemometrics
chemistry.chemical_compound
Silicone
Response prediction
Linear regression
Calibration
Multiple linear regression
0105 earth and related environmental sciences
Gas chromatography
Chromatography
Organic chemicals
010401 analytical chemistry
0104 chemical sciences
Automated mass spectral deconvolution and identification system (AMDIS)
chemistry
Environmental science
Gas chromatography–mass spectrometry
Research Paper
Subjects
Details
- Language :
- English
- ISSN :
- 16182650 and 16182642
- Volume :
- 410
- Issue :
- 13
- Database :
- OpenAIRE
- Journal :
- Analytical and Bioanalytical Chemistry
- Accession number :
- edsair.doi.dedup.....888429812640a15f8437664c14025f65