Back to Search
Start Over
Influence of image acquisition settings on radiation dose and image quality in coronary angiography by 320-detector volume computed tomography: the CORE320 pilot experience
- Source :
- Heart International, Vol 7, Iss 2, Pp e11-e11 (2012), Heart International
- Publication Year :
- 2012
- Publisher :
- Touch Medical Media, 2012.
-
Abstract
- The objective of this study was to investigate the impact of image acquisition settings and patients’ characteristics on image quality and radiation dose for coronary angiography by 320-row computed tomography (CT). CORE320 is a prospective study to investigate the diagnostic performance of 320-detector CT for detecting coronary artery disease and associated myocardial ischemia. A run-in phase in 65 subjects was conducted to test the adequacy of the computed tomography angiography (CTA) acquisition protocol. Tube current, exposure window, and number of cardiac beats per acquisition were adjusted according to subjects’ gender, heart rate, and body mass index (BMI). Main outcome measures were image quality, assessed by contrast/noise measurements and qualitatively on a 4-point scale, and radiation dose, estimated by the dose-length-product. Average heart rate at image acquisition was 55.0±7.3 bpm. Median Agatston calcium score was 27.0 (interquartile range 1-330). All scans were prospectively triggered. Single heart beat image acquisition was obtained in 61 of 65 studies (94%). Sixty-one studies (94%) and 437 of 455 arterial segments (96%) were of diagnostic image quality. Estimated radiation dose was significantly greater in obese (5.3±0.4 mSv) than normal weight (4.6±0.3 mSv) or overweight (4.7±0.3 mSv) subjects (P
- Subjects :
- medicine.medical_specialty
lcsh:Diseases of the circulatory (Cardiovascular) system
CT angiography, image acquisition, image quality, radiation dose, body mass index, contrast to noise ratio
Image quality
body mass index
030204 cardiovascular system & hematology
image acquisition
Coronary artery disease
03 medical and health sciences
0302 clinical medicine
Contrast-to-noise ratio
Interquartile range
Heart rate
Medicine
image quality
030212 general & internal medicine
Clinical Investigation
Prospective cohort study
Computed tomography angiography
medicine.diagnostic_test
business.industry
medicine.disease
contrast to noise ratio
CT angiography
lcsh:RC666-701
Radiology
Cardiology and Cardiovascular Medicine
business
radiation dose
Body mass index
Subjects
Details
- Language :
- English
- ISSN :
- 20362579 and 18261868
- Volume :
- 7
- Issue :
- 2
- Database :
- OpenAIRE
- Journal :
- Heart International
- Accession number :
- edsair.doi.dedup.....8835d83a33abe0c5fcf0d059f109532e