Back to Search Start Over

Biomechanical caracterisation of lumbar belt by full-field techniques: Preliminary results

Authors :
Rébecca Bonnaire
Jérôme Molimard
Paul Calmels
Reynald Convert
Centre Ingénierie et Santé (CIS-ENSMSE)
École des Mines de Saint-Étienne (Mines Saint-Étienne MSE)
Institut Mines-Télécom [Paris] (IMT)-Institut Mines-Télécom [Paris] (IMT)
Thuasne
Surfaces et Tissus Biologiques (STBio-ENSMSE)
Institut Mines-Télécom [Paris] (IMT)-Institut Mines-Télécom [Paris] (IMT)-CIS
Institut Fédératif de Recherche en Sciences et Ingénierie de la Santé (IFRESIS-ENSMSE)
Institut Mines-Télécom [Paris] (IMT)-Institut Mines-Télécom [Paris] (IMT)-IFR143
Laboratoire Georges Friedel (LGF-ENSMSE)
Institut Mines-Télécom [Paris] (IMT)-Institut Mines-Télécom [Paris] (IMT)-Université de Lyon-Centre National de la Recherche Scientifique (CNRS)
Service de médecine physique et de réadaptation (MPR)
Hôpital Bellevue, CHU de Saint-Étienne
Chrysoochos
André
Louche
Hervé
Wattrisse
Bertrand
CHU de Saint Etienne
Service de Médecine Physique et de Réadaptation (MPR)
Source :
Proceedings of Photomechanics 2013, PhotoMechanics 2013, PhotoMechanics 2013, May 2013, Montpellier, France, HAL
Publication Year :
2013
Publisher :
HAL CCSD, 2013.

Abstract

International audience; In France, 50% of the population per year is suffering from low back pain. Lumbar belt are frequently proposed as a part of the treatment of this pathology. However mechanical ways of working of this medical device is not clearly understood, but abdominal pressure is often related. So an optical method was developed in this study to measure strain in lumbar belt and trunk interface and to derive a pressure estimation. Optical method consisted of coupling fringe projection and digital image correlation (DIC). Measurement has been carried out on the right side of a manikin wearing a lumbar belt. Average strain is 0.2 and average pressure is 1 kPa. Continuation of this study will be comparison of strain and pressure in different areas of lumbar belt (left side, front and back) and comparison of different lumbar belts. Results will be used in a finite elements model to determine lumbar belt impact in intern body. In long term, this kind of study will be done on human.

Details

Language :
English
Database :
OpenAIRE
Journal :
Proceedings of Photomechanics 2013, PhotoMechanics 2013, PhotoMechanics 2013, May 2013, Montpellier, France, HAL
Accession number :
edsair.doi.dedup.....87dc67545474200cc605832243b13503