Inter-reader agreement of magnetic resonance imaging proton density fat fraction and its longitudinal change in a clinical trial of adults with nonalcoholic steatohepatitis

Authors :
Cheng William Hong
Steven Liao
Gavin Hamilton
Jonathan Hooker
Tanya Wolfson
Anthony Gamst
Soudabeh Fazeli Dehkordy
Claude B. Sirlin
Rohit Loomba
Charlie C. Park
Adrija Mamidipalli
Source :
Abdominal radiology (New York), vol 44, iss 2, Hooker, Jonathan C; Hamilton, Gavin; Park, Charlie C; Liao, Steven; Wolfson, Tanya; Dehkordy, Soudabeh Fazeli; et al.(2018). Inter-reader agreement of magnetic resonance imaging proton density fat fraction and its longitudinal change in a clinical trial of adults with nonalcoholic steatohepatitis.. Abdominal radiology (New York). doi: 10.1007/s00261-018-1745-3. UC San Diego: Retrieved from: http://www.escholarship.org/uc/item/34z7k2zz
Publication Year :
2018
Publisher :
Springer Science and Business Media LLC, 2018.

Abstract

PURPOSE:To determine the inter-reader agreement of magnetic resonance imaging proton density fat fraction (PDFF) and its longitudinal change in a clinical trial of adults with nonalcoholic steatohepatitis (NASH). STUDY TYPE:We performed a secondary analysis of a placebo-controlled randomized clinical trial of a bile acid sequestrant in 45 adults with NASH. A six-echo spoiled gradient-recalled-echo magnitude-based fat quantification technique was performed at 3T. Three independent readers measured MRI-PDFF by placing one primary and two additional regions of interest (ROIs) in each segment at both time points. Cross-sectional agreement between the three readers was evaluated using intra-class correlation coefficients (ICCs) and coefficients of variation (CV). Additionally, we used Bland-Altman analyses to examine pairwise agreement between the three readers at baseline, end of treatment (EOT), and for longitudinal change. RESULTS:Using all ROIs by all readers, mean PDFF at baseline, at EOT, and mean change in PDFF was 16.1%, 16.0%, and 0.07%, respectively. The 27-ROI PDFF measurements had 0.998 ICC and 1.8% CV at baseline, 0.998 ICC and 1.8% CV at EOT, and 0.997 ICC for longitudinal change. The 9-ROI PDFF measurements had corresponding values of 0.997 and 2.6%, 0.996 and 2.4%, and 0.994. Using 27 ROIs, the magnitude of the bias between readers for whole-liver PDFF measurement ranged from 0.03% to 0.06% points at baseline, 0.01% to 0.07% points at EOT, and 0.01% to 0.02% points for longitudinal change. CONCLUSION:Inter-reader agreement for measuring whole-liver PDFF and its longitudinal change is high. 9-ROI measurements have only slightly lower agreement than 27-ROI measurements.

Details

ISSN :
23660058 and 2366004X
Volume :
44
Database :
OpenAIRE
Journal :
Abdominal Radiology
Accession number :
edsair.doi.dedup.....87140969491dc282ff488b4d50c25305
Full Text :
https://doi.org/10.1007/s00261-018-1745-3